2015
DOI: 10.1016/j.jmbbm.2015.01.007
|View full text |Cite
|
Sign up to set email alerts
|

Time course of bone screw fixation following a local delivery of Zoledronate in a rat femoral model – A micro-finite element analysis

Abstract: Hydrogel BisphosphonateScrew fixation microCT microFE a b s t r a c t A good fixation of osteosynthesis implants is crucial for a successful bone healing but often difficult to achieve in osteoporotic patients. One possible solution to this issue is the local delivery of bisphosphonates in direct proximity to the implants, A critical aspect of this method, that has not yet been well investigated, is the time course of the implant fixation following the drug release. Usual destructive mechanical tests require l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 32 publications
0
11
0
Order By: Relevance
“…Our model enables longitudinal, time‐dependent measurements of bone distribution, changes and of the resulting implant fixation. Since this approach was first reported it was successfully used to describe bone dynamics around bisphosphonate‐releasing implants, around infected implants and in osteoporotic animals . But to acquire images with high enough quality, BaSO 4 loaded PEEK screws are used, instead of more standard stainless steel or titanium screws, which would generate metallic artifacts in tomographic reconstructions .…”
Section: Discussionmentioning
confidence: 99%
“…Our model enables longitudinal, time‐dependent measurements of bone distribution, changes and of the resulting implant fixation. Since this approach was first reported it was successfully used to describe bone dynamics around bisphosphonate‐releasing implants, around infected implants and in osteoporotic animals . But to acquire images with high enough quality, BaSO 4 loaded PEEK screws are used, instead of more standard stainless steel or titanium screws, which would generate metallic artifacts in tomographic reconstructions .…”
Section: Discussionmentioning
confidence: 99%
“…We evaluated octahedral shear strain of all patellae [18] , for the isotropic and anisotropic models, and for the non-resurfaced and resurfaced cases. To compare isotropy to anisotropy, we calculated for the two cases the volume of bone with a strain above a threshold value.…”
Section: Methodsmentioning
confidence: 99%
“…The octahedral shear strain invariant was evaluated within the tibial bone (Nagaraja et al 2005;Kettenberger et al 2015). Within the manuscript, strain always refer to this invariant.…”
Section: A C C E P T E D Mmentioning
confidence: 99%