2000
DOI: 10.1016/s0584-8547(00)00181-6
|View full text |Cite
|
Sign up to set email alerts
|

Time-of-flight mass spectrometry as a tool for speciation analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
31
0

Year Published

2000
2000
2007
2007

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 44 publications
(31 citation statements)
references
References 34 publications
0
31
0
Order By: Relevance
“…Exceptional attributes of ICP-TOF-MS, such as high speed of data acquisition, an ability to obtain a full elemental analysis in a time-frame suited to a transient inlet system and significantly better, as compared with widely used quadrupole ICP-MS, the precision of the measurements generate increasing interest in the technique. The ICP-TOF-MS has been successfully coupled to LA, [120][121][122][123][124][125][126] ETV, 127 GC, [128][129][130][131][132] liquid chromatography, 133,134 CE 135,136 and FIA. [137][138][139][140][141] Detailed reviews of the development and analytical performance of TOF-MS combined with ICP ion source have been presented.…”
Section: An Overview Of Analytical Applications Of Tof-ms Analyzersmentioning
confidence: 99%
See 1 more Smart Citation
“…Exceptional attributes of ICP-TOF-MS, such as high speed of data acquisition, an ability to obtain a full elemental analysis in a time-frame suited to a transient inlet system and significantly better, as compared with widely used quadrupole ICP-MS, the precision of the measurements generate increasing interest in the technique. The ICP-TOF-MS has been successfully coupled to LA, [120][121][122][123][124][125][126] ETV, 127 GC, [128][129][130][131][132] liquid chromatography, 133,134 CE 135,136 and FIA. [137][138][139][140][141] Detailed reviews of the development and analytical performance of TOF-MS combined with ICP ion source have been presented.…”
Section: An Overview Of Analytical Applications Of Tof-ms Analyzersmentioning
confidence: 99%
“…The capabilities of ICP-TOF-MS coupled with CE (and GC) for speciation analysis have been discussed. 136 The advantages of ICP-TOF-MS over sequential mass analyzers for fast transient detection and the simultaneous determination of a large number of isotopes in the flow injection (FI) peaks in trace metal analysis have been discussed. [137][138][139][140][141] The absence of spectral skew is highly appreciated.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
“…The speciation of inorganic forms of arsenic has been reported in CE systems with detection by proton-induced X-ray emission (PIXE) [48], and by time-of-flight mass spectrometry (TOFMS) [66]. In the first case the appropriate capillary preparation provided PIXE signals for separated HAsO 4 2 -and H 2 AsO 3 -species with similar sensitivity for both analytes in contrast to UV indirect detection, exhibits very different sensitivity for the two separated species.…”
Section: Arsenicmentioning
confidence: 99%
“…In the first case the appropriate capillary preparation provided PIXE signals for separated HAsO 4 2 -and H 2 AsO 3 -species with similar sensitivity for both analytes in contrast to UV indirect detection, exhibits very different sensitivity for the two separated species. In the CE-ICP-TOFMS system As(III) and As(V) were separated as cyanide complexes in polyacrylamidecoated capillary at -30 kV voltage combined with a forward hydrodynamic flow caused by a capillary head pressure [66]. Also, speciation of inorganic arsenic forms only was reported with the use of direct UV detection.…”
Section: Arsenicmentioning
confidence: 99%
“…These devices can monitor the entire mass range of interest continuously and simultaneously (4). TOFMS has also been explored as a method for overcoming some of the limitations of PSMS and is gaining popularity for multielemental and multiisotopic analysis of fast transient signals (5)(6)(7)(8).…”
mentioning
confidence: 99%