2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC) 2013
DOI: 10.1109/nssmic.2013.6829520
|View full text |Cite
|
Sign up to set email alerts
|

Timing resolution performance comparison for fast and standard outputs of SensL SiPM

Abstract: A new silicon photomultiplier (SiPM) with a unique fast output signal feature was recently introduced by SensL. For a SiPM device with 3×3 mm 2 sensitive area, the single photo electron response from the fast output is less than 2 ns wide compared with 50 ns width observed at the standard output. Using the fast readout signal, a coincidence resolving time (CRT) of 190 ps (FWHM -full width at half maximum) was measured with a 3×3×10 mm 3 LYSO crystal optically coupled to the SiPM mounted on the SensL MicroFB-SM… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2016
2016
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 6 publications
1
11
0
Order By: Relevance
“…The best achieved resolutions for the "benchmark" and "PET" crystals are 130 ps and 200 ps, respectively. Such values are comparable to the state-of-the-art performance with commercial LYSO reported in literature [13,14,[21][22][23]), proving that the NUV technology is suited for PET.…”
Section: Benchmark and Pet Crystalssupporting
confidence: 81%
See 1 more Smart Citation
“…The best achieved resolutions for the "benchmark" and "PET" crystals are 130 ps and 200 ps, respectively. Such values are comparable to the state-of-the-art performance with commercial LYSO reported in literature [13,14,[21][22][23]), proving that the NUV technology is suited for PET.…”
Section: Benchmark and Pet Crystalssupporting
confidence: 81%
“…We tested the energy and timing resolution with two "Test" LYSO scintillators with dimensions of 2.8 × 2.8 × 3 mm 3 and 2.8 × 2.8 × 10 mm 3 . Since the active area is slightly smaller than the die area (because of a safety margin between the cells and the cut line), it was not possible to couple them with the typical "benchmark" crystal 3 × 3 × 5 mm 3 , widely used in literature [9,13,14,[21][22][23]. We then selected a fourth device having a die size of 4 × 4 mm 2 and a R q of 850 kΩ (τ = 80 ns), and coupled it with LYSO with different size: "benchmark" 3 × 3 × 5 mm 3 , "PET" 3.8 × 3.8 × 22 mm 3 , as well as the two "Test" scintillators.…”
Section: Methodsmentioning
confidence: 99%
“…SensL-JD4 was optimized by the producers for a reduced signal delay time spread. SensL devices were operated in the regular configuration and not in the fast output as described in [13].…”
Section: Description Of the Devicesmentioning
confidence: 99%
“…An interesting way to mitigate these requirements is by equipping the SiPM with an additional terminal that is parallel-connected to all of the individual diodes through small capacitances (Dolinsky et al 2013, Yeom et al 2013, Jackson et al 2014. Such a 'fast' output can have an equivalent capacitance that is one or two orders of magnitude smaller than the anode-cathode capacitance.…”
Section: Readout Of Sipm-based Scintillation Detectorsmentioning
confidence: 99%
“…One may also consider high-pass filtering, e.g. by means of the previously discussed fast output (Yeom et al 2013, Jackson et al 2014 or an external CR filter (Dolinsky et al 2013, Bieniosek et al 2016a. However, the baseline may not be restored perfectly, as the application of a simple CR filter to exponentially decaying pulses tends to give rise to undershoot.…”
Section: Readout Of Sipm-based Scintillation Detectorsmentioning
confidence: 99%