2010
DOI: 10.1016/j.susc.2010.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Topmost-surface-sensitive Si-2p photoelectron spectra of clean Si(100)-2×1 measured with photoelectron Auger coincidence spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…22 Very recently, we measured Si L 23 VV Auger electron Si 2p photoelectron coincidence spectra (Si 2p-Si L 23 VV PEACS) of Si(100)-2×1, and identified the topmostsurface Si 2p components by taking advantage of the extremely short escape depth of 1.2Å. 23 In this paper, we report on the surface-site-selective Si L 23 VV AES and Si 2p PES of clean Si(111)-7×7 measured with Si L 23 VV-Si 2p APECS and Si 2p-Si L 23 VV PEACS. The Si L 23 VV-Si 2p APECS indicated that the valence band in the vicinity of the rest atoms shifted towards the Fermi level (E F ) relative to that of the pedestal atoms.…”
Section: Introductionmentioning
confidence: 99%
“…22 Very recently, we measured Si L 23 VV Auger electron Si 2p photoelectron coincidence spectra (Si 2p-Si L 23 VV PEACS) of Si(100)-2×1, and identified the topmostsurface Si 2p components by taking advantage of the extremely short escape depth of 1.2Å. 23 In this paper, we report on the surface-site-selective Si L 23 VV AES and Si 2p PES of clean Si(111)-7×7 measured with Si L 23 VV-Si 2p APECS and Si 2p-Si L 23 VV PEACS. The Si L 23 VV-Si 2p APECS indicated that the valence band in the vicinity of the rest atoms shifted towards the Fermi level (E F ) relative to that of the pedestal atoms.…”
Section: Introductionmentioning
confidence: 99%
“…This is due to the fact that both the photoelectron and the Auger electron signals are attenuated due to the finite mean free path, which implies that the coincidence signal attenuates as a product of these effects. This increased surface sensitivity of APECS was for in-stance used to enhance the Si2p signal from the outermost Si atoms for the reconstructed Si(100) 2x1 surface [18]. Using APECS it is also possible to tune the surface sensitivity for the Auger spectra.…”
Section: Auger Photoelectron Coincidence Spectroscopy -Apecsmentioning
confidence: 99%
“…From the pioneering experiment performed by Haak et al [21], which demonstrated the feasibility of APECS, the experimental advances, particularly the development of multichannel electron detectors and the advent of energy tunable synchrotron radiation sources stimulated a renewed interest in the study of Auger line shapes of solid [23][24][25] and molecular targets [26][27][28]. A number of experiments conducted to date have shown that APECS has the ability to: isolate individual sites in a solid and probe their local electronic structure [29][30][31], separate overlapping spectral features [32][33][34], probe electronic structure with extremely high surface sensitivity [35][36][37].…”
Section: Introductionmentioning
confidence: 99%