2021
DOI: 10.1039/d0tc05193d
|View full text |Cite
|
Sign up to set email alerts
|

Total internal reflection ellipsometry for kinetics-based assessment of bovine serum albumin immobilization on ZnO nanowires

Abstract: The properties of the ZnO-NWs were investigated by utilizing spectroscopic ellipsometry under TIRE configuration during real-time measurement of covalent BSA immobilization.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 28 publications
0
10
0
Order By: Relevance
“…For the evaluation of SCoV2-N covalent immobilization on 11-MUA SAM and SCoV2-N/anti-SCoV2-N complex formation on the gold-coated sensor disk, measurements of ellipsometric parameters ( Δ and Ψ ) were performed simultaneously with QCM-D signals registration (Δ F and Δ D ). Here we present only the kinetics of the ellipsometric parameter Δ due to its higher sensitivity [16] , [22] , [39] . The simulation of ellipsometric parameters Ψ and Δ vs λ has been conducted to determine the difference between the optical properties in case of full coverage by SCoV2-N and anti-SCoV2-N versus partial coverage by the same proteins.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For the evaluation of SCoV2-N covalent immobilization on 11-MUA SAM and SCoV2-N/anti-SCoV2-N complex formation on the gold-coated sensor disk, measurements of ellipsometric parameters ( Δ and Ψ ) were performed simultaneously with QCM-D signals registration (Δ F and Δ D ). Here we present only the kinetics of the ellipsometric parameter Δ due to its higher sensitivity [16] , [22] , [39] . The simulation of ellipsometric parameters Ψ and Δ vs λ has been conducted to determine the difference between the optical properties in case of full coverage by SCoV2-N and anti-SCoV2-N versus partial coverage by the same proteins.…”
Section: Resultsmentioning
confidence: 99%
“…This model consisted of a thick QCM-D gold substrate, thickness d (gold) = 200 nm, covered by 11-MUA SAM, d (SAM) = 0.8 nm and d (SCoV2-N) = 5.9 nm SCoV2-N layers. The refractive index dispersion of the QCM-D gold-coated sensor substrate was modelled using B-Spline function [24] , 11-MUA SAM was modelled by Cauchy dispersion ( n =1.450) and the SCoV2-N monolayer was described using the Bruggeman effective media approach (EMA) [22] , [39] , [40] , [41] .…”
Section: Resultsmentioning
confidence: 99%
“…Ellipsometry in total internal reflection mode (TIRE) is a powerful tool for applications in biosensing [32,33,69,70]. In many cases during the application of TIRE, the high sensitivity of SE is combined with that of the surface plasmon resonance (SPR).…”
Section: Application Of Spectroscopic Ellipsometry For the Assessment...mentioning
confidence: 99%
“…However, in most photoluminescence-based ways, additional photoluminescence probes should be applied, which sometimes is a significant drawback because they need additional expensive chemicals such as antibodies conjugated with photoluminescence probe [ 314 316 ]. This drawback can be avoided when Surface Plasmon Resonance (SPR) based sensors [ 309 311 , 317 ] and spectroscopic ellipsometry [ 318 325 ] based methods are applied. In addition, these sensors are less sophisticated in comparison with more sensitive optical methods.…”
Section: Molecular and Non-molecular Virus Detection Techniquesmentioning
confidence: 99%