2020
DOI: 10.1016/j.bios.2020.112152
|View full text |Cite
|
Sign up to set email alerts
|

Towards a catheter-based impedimetric sensor for the assessment of intestinal histamine levels in IBS patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
21
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(22 citation statements)
references
References 63 publications
1
21
0
Order By: Relevance
“…They coated titanium electrode wires in a catheter with an adhesive polystyrene layer onto which they immobilized both MIP and non-imprinted particles by dip coating in order to obtain a differential measurement setup (see Fig. 2 ) [ 85 ]. The resulting sensor was able to detect histamine in intestinal fluid in physiologically relevant concentrations, illustrating the potential of MIP-based sensing for in vivo monitoring gastro-intestinal disease markers.…”
Section: Mips As Receptors In Sensing Devicesmentioning
confidence: 99%
See 2 more Smart Citations
“…They coated titanium electrode wires in a catheter with an adhesive polystyrene layer onto which they immobilized both MIP and non-imprinted particles by dip coating in order to obtain a differential measurement setup (see Fig. 2 ) [ 85 ]. The resulting sensor was able to detect histamine in intestinal fluid in physiologically relevant concentrations, illustrating the potential of MIP-based sensing for in vivo monitoring gastro-intestinal disease markers.…”
Section: Mips As Receptors In Sensing Devicesmentioning
confidence: 99%
“…This patch, containing an integrated PDMS flow cell and a measuring chamber were attached to a test person’s arm, allowing to monitor lactate levels in sweat. Reproduced with permission from [ 85 ]. Copyright Elsevier 2020.…”
Section: Mips As Receptors In Sensing Devicesmentioning
confidence: 99%
See 1 more Smart Citation
“…For the mycotoxin deoxynivalenol [155], Nyquist plots determined charge transfer resistance (R ct ) increase with toxin MIP binding, response turned out to be log‐linear. An extreme demand on any sensor is use for in situ clinical monitoring, but the possibility has been shown in principle using an impedance catheter design for duodenal histamine in subjects with irritable bowel syndrome (IBS) [156]. A technically demanding broad frequency range was needed with convoluted data extraction using multiple equivalent circuits to obtain interference free resistive information signifying MIP binding.…”
Section: Mip Based Impedimetric Sensorsmentioning
confidence: 99%
“…When amperometric electrodes, one of the electrochemical analytical methods, are utilized for HA determination, a high potential is necessary for a redox reaction with which to detect the current characteristics, and the redox product is unfavorable for the nervous system [ 21 , 22 ]. Although modern impedimetric electrodes, another electrochemical method, minimize unwanted cell depolarization with lower voltages [ 23 ], the complex models and analyses are not universal [ 24 ].…”
Section: Introductionmentioning
confidence: 99%