2008
DOI: 10.1016/j.clinph.2007.09.121
|View full text |Cite
|
Sign up to set email alerts
|

Towards an independent brain–computer interface using steady state visual evoked potentials

Abstract: Objective-Brain -computer interface (BCI) systems using steady state visual evoked potentials (SSVEPs) have allowed healthy subjects to communicate. However, these systems may not work in severely disabled users because they may depend on gaze shifting. This study evaluates the hypothesis that overlapping stimuli can evoke changes in SSVEP activity sufficient to control a BCI. This would provide evidence that SSVEP BCIs could be used without shifting gaze.Methods-Subjects viewed a display containing two images… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
183
0
4

Year Published

2010
2010
2023
2023

Publication Types

Select...
4
3
2

Relationship

2
7

Authors

Journals

citations
Cited by 285 publications
(197 citation statements)
references
References 42 publications
4
183
0
4
Order By: Relevance
“…Mean online accuracy on healthy subjects able to communicate was 80.3 ± 8.6%. Offline analysis showed that healthy subjects succeeded in reaching an average accuracy of 85% (with three subjects out of ten reaching more than 94%), which exceeds accuracies of previous covert SSVEP-based BCIs [18][19][20]. Moreover, the proposed 'interlaced squares' stimulation pattern is small, portable, easy to use and adapted for bedside use with patients, features which are not shared by other covert stimulation devices requiring a cathode ray tube screen.…”
Section: Discussionmentioning
confidence: 80%
See 1 more Smart Citation
“…Mean online accuracy on healthy subjects able to communicate was 80.3 ± 8.6%. Offline analysis showed that healthy subjects succeeded in reaching an average accuracy of 85% (with three subjects out of ten reaching more than 94%), which exceeds accuracies of previous covert SSVEP-based BCIs [18][19][20]. Moreover, the proposed 'interlaced squares' stimulation pattern is small, portable, easy to use and adapted for bedside use with patients, features which are not shared by other covert stimulation devices requiring a cathode ray tube screen.…”
Section: Discussionmentioning
confidence: 80%
“…The panel, placed at 30 cm from subject's head, is a 7 × 7 cm 2 'interlaced square' made of red and yellow 1 × 1 cm 2 light emitting diode (LED)-squares with a white fixation cross in the middle (see figure 1). The interlaced square pattern showed a 10% improvement in accuracy in comparison with a 'line' pattern [19]. The control unit is an electronic embedded system used for precise control of red and yellow flickering frequencies, which can be varied independently between 1 and 99 Hz by a programmable integrated circuit microcontroller.…”
Section: Data Collectionmentioning
confidence: 99%
“…On the other hand, P300-based BCIs are much less dependent than steady-state visual evoked potentials based BCIs on eye-movement control. Steady-state visual evoked potentials have been used for binary selection, [48][49][50][51] both discrete and continuous control of a cursor in 2 dimensions, 52 prosthesis control, 53 FES, 54,55 spelling, 56 and environmental control. 57 For patients with impaired vision, various auditory 39,40,[58][59][60][61] and tactile [62][63][64][65] paradigms have been investigated.…”
Section: Device Outputmentioning
confidence: 99%
“…Cette exigence ne pose aucun problème pour des sujets sains, mais limite fortement l'application de l'interface chez des patients dont le handicap moteur s'étend au contrôle oculaire (altéré ou inexistant). Afin de pouvoir utiliser ce système indépendamment du contrôle du regard, l'utilisation de l'attention implicite (covert attention) a été proposée [24][25][26]. Dans cette situation, le sujet se concentre mentalement sur le stimulus cible sans bouger les yeux.…”
Section: Vers Un Paradigme Visuel Indépendantunclassified