Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: Removing Gibbs ringing effects using optimized radial imaging

Abstract: Purpose Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of the DRA is known to be the “Gibbs ringing” effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-induced DRAs in FPP. Theory and Methods By studying the underlying point spread function (PSF), we show that optimized radial sampling with a simple reconstruction method can elimin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
35
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
10

Relationship

6
4

Authors

Journals

citations
Cited by 30 publications
(35 citation statements)
references
References 63 publications
0
35
0
Order By: Relevance
“…utilizes a similar approach. 29 A higher readout bandwidth is used to achieve a higher spatial resolution with the same readout duration at the cost of a reduction in SNR. The data is apodized (in their case by a Gaussian filter) to remove residual ringing artifacts, effectively under-weighting the high spatial frequencies and recovering SNR.…”
Section: Discussionmentioning
confidence: 99%
“…utilizes a similar approach. 29 A higher readout bandwidth is used to achieve a higher spatial resolution with the same readout duration at the cost of a reduction in SNR. The data is apodized (in their case by a Gaussian filter) to remove residual ringing artifacts, effectively under-weighting the high spatial frequencies and recovering SNR.…”
Section: Discussionmentioning
confidence: 99%
“…20 Radial perfusion CMR is well suited for continuous acquisition and self-gating, effectively eliminating the need for ECG gating, and has the potential to achieve high diagnostic accuracy in arrhythmic patients. 21 Radial perfusion imaging, using a slice-interleaved continuous approach (Figure 3C), has demonstrated potential for acquiring high-resolution perfusion images (1.4 mm in-plane) at the end-systolic phase without the need for ECG gating.…”
Section: Advanced Techniques and Applications For First-pass Perfusiomentioning
confidence: 99%
“…42 Results of CMR have correlated well with results from invasive measurement. 43 A drawback of CMR is the subendocardial dark-rim artifact, which lowers the diagnostic accuracy of ischemia, but optimized radial imaging has significantly reduced such artifact 44 (Figure 3). CMR is useful for assessing the prognosis of patients with ischemic heart disease.…”
Section: Cardiovascular Magnetic Resonance (Cmr)mentioning
confidence: 99%