2018
DOI: 10.1016/j.nimb.2018.09.046
|View full text |Cite
|
Sign up to set email alerts
|

Towards the limits: Analysis of microscale 14C samples using EA-AMS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1
1

Relationship

4
5

Authors

Journals

citations
Cited by 32 publications
(29 citation statements)
references
References 31 publications
1
28
0
Order By: Relevance
“…Sn boats and capsules thus introduce similar amounts of contamination. Our results determined with blank material combusted in Sn containers are in a similar range to results of other studies, which however combusted empty Sn containers including Welte et al (2018; We have so far not tested heat treatment (550°C) of DCM-washed Sn vessels, which can further reduce contamination levels (Welte et al 2018). The size series combusted in Ag capsules gave 14 C concentrations, which are about one order of magnitude higher, between 0.1921 ± 0.0293 -0.5492 ± 0.0322 F 14 C, than for the Sn containers and the data show no size dependency but scatter strongly (Figure 3).…”
Section: Ea-gis-ams Measurementssupporting
confidence: 91%
See 1 more Smart Citation
“…Sn boats and capsules thus introduce similar amounts of contamination. Our results determined with blank material combusted in Sn containers are in a similar range to results of other studies, which however combusted empty Sn containers including Welte et al (2018; We have so far not tested heat treatment (550°C) of DCM-washed Sn vessels, which can further reduce contamination levels (Welte et al 2018). The size series combusted in Ag capsules gave 14 C concentrations, which are about one order of magnitude higher, between 0.1921 ± 0.0293 -0.5492 ± 0.0322 F 14 C, than for the Sn containers and the data show no size dependency but scatter strongly (Figure 3).…”
Section: Ea-gis-ams Measurementssupporting
confidence: 91%
“…In addition, we tested different EA sample containers including Sn boats and capsules cleaned with DCM, which removes contamination more efficient than Acetone or Milli-Q water (Welte et al 2018;Ruff et al 2010a), and Ag capsules cleaned by heating at 450°C. To directly compare the results for the Sn boats and Sn capsules, we calculated the amount of exogenous C for each series using the parameters obtained from the combined ampoule data set (F 14 C c = 0.93 ± 0.23) ( Table 1).…”
Section: Ea-gis-ams Measurementsmentioning
confidence: 99%
“…Both the cleaned canvas material and paint sample were directly measured on the AMS as carbon dioxide following combustion in an elemental analyzer (8). Owing to the ultrasmall sample size, constant contamination was considered and accordingly corrected (33, 34). Radiocarbon results are reported as 14 C ages (before 1950) and as fraction modern F 14 C for samples younger than 1950 (35).…”
Section: Methodsmentioning
confidence: 99%
“…The reextracted and pre-heated n-alkane fractions (step 2) were analyzed at the LIP AMS (ETH Nr's.). F 14 C results were corrected for constant contamination according to Welte et al (2018) with a fossil n-alkane standard (C28 with F 14 C = 0) and a modern n-alkane standard (C32 with F 14 C = 1.073). Constant contamination correction yielded 4.3 µg C for a single cap, with F 14 C values of 0.895.…”
Section: C Measurementsmentioning