Towards understanding the limits of distortion product otoacoustic emission measurements

Abstract: Distortion product otoacoustic emission (DPOAE) data were obtained with a custom-designed system from 20 subjects with normal hearing. Cavity measurements, using this system and an Etymotic ER-10B low-noise microphone system, resulted in estimates of recording system distortion of -20 dB SPL for f2 frequencies ranging from 500 to 8000 Hz, and primary levels ranging from 20 to 75 dB SPL (L2 = L1-10 dB). Using this system it was possible to automatically adjust averaging time in order to obtain the same residual… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
9
0

Year Published

1995
1995
2016
2016

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 42 publications
(12 citation statements)
references
References 0 publications
3
9
0
Order By: Relevance
“…The first step in this approach is to study the relationship between OAE I/O functions and BM response growth. DPOAE I/O functions have been reported by several investigators ͑Lonsbury- Martin et al, 1990;Gorga et al, 1994;Whitehead et al, 1995;Kummer et al, 1998;Withnell and Yates, 1998;Buus et al, 2001;Dorn et al, 2001͒. Withnell and Yates ͑1998͒, for example, recorded DPOAE I/O functions in guinea pigs that were comparable in form to the BM I/O functions reported in the literature. Their DPOAE I/O functions were characterized by an approximately linear slope at low stimulus levels, a breakpoint of 22 to 33 dB SPL, and an upper slope of 0.14 to 0.27 dB/dB.…”
Section: B Relationship Of Bm Response Growth To Behavioral Measuremsupporting
confidence: 67%
“…The first step in this approach is to study the relationship between OAE I/O functions and BM response growth. DPOAE I/O functions have been reported by several investigators ͑Lonsbury- Martin et al, 1990;Gorga et al, 1994;Whitehead et al, 1995;Kummer et al, 1998;Withnell and Yates, 1998;Buus et al, 2001;Dorn et al, 2001͒. Withnell and Yates ͑1998͒, for example, recorded DPOAE I/O functions in guinea pigs that were comparable in form to the BM I/O functions reported in the literature. Their DPOAE I/O functions were characterized by an approximately linear slope at low stimulus levels, a breakpoint of 22 to 33 dB SPL, and an upper slope of 0.14 to 0.27 dB/dB.…”
Section: B Relationship Of Bm Response Growth To Behavioral Measuremsupporting
confidence: 67%
“…In the case of hearing loss, then, one might naively expect that emissions would "predict" or be wellcorrelated with hearing function, for example, as measured by pure-tone thresholds or auditory brain stem response (ABR) thresholds. There is now ample evidence that there is no measure of emissions that does very well in predicting hearing thresholds, both in infants and in adults with impaired hearing (Gorga et al, 1994;Gorga et al, 1999;Gorga et al, 2003;Norton et al, 2000;Stover et al, 1996). For this reason, for example, it can be asserted that no type of emission measurement can adequately replace ABR in infant screening because there may be emissions present even in cases with severe hearing loss.…”
Section: Meaning and Interpretation Of Emission Measurementsmentioning
confidence: 94%
“…They attributed the larger variability in lower frequency regions to environmental and instrumentation noise. Various researchers, on the other hand, have theorized that forward and reverse middle ear transmission and cochlear nonlinear behaviour could explain for the adverse effect of environmental noise on DPOAEs at lower frequencies (Gorga et al, 1994). Roede et al (1993) used the stimulus level of 70 and 55 dB SPL (with primary tones delivered at equal intensities, i.e.…”
Section: Sumariomentioning