1996
DOI: 10.1002/(sici)1098-2256(1996)11:1<13::aid-tox3>3.0.co;2-c
|View full text |Cite
|
Sign up to set email alerts
|

Toxicity of zinc in three microbial test systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

1999
1999
2015
2015

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 10 publications
0
9
0
Order By: Relevance
“…The Microtox and P. phosphoreum bioassays use two strains of the same bacterial species, Photobacterium phosphoreum. Strain 11177, used in the Microtox bioassay, is highly sensitive to contaminants (http://www.azurenv.com) including metals (Codina et al, 1993;Ghosh et al, 1996). Indeed, the toxicity response of the P. phosphoreum Microtox bioassay to Cr, Mn, and Zn contrasted with the lack of effect of the same metals with similar speciation on the wild strain of P. phosphoreum.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Microtox and P. phosphoreum bioassays use two strains of the same bacterial species, Photobacterium phosphoreum. Strain 11177, used in the Microtox bioassay, is highly sensitive to contaminants (http://www.azurenv.com) including metals (Codina et al, 1993;Ghosh et al, 1996). Indeed, the toxicity response of the P. phosphoreum Microtox bioassay to Cr, Mn, and Zn contrasted with the lack of effect of the same metals with similar speciation on the wild strain of P. phosphoreum.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, assuming that toxicity is related to metal speciation, a toxicity assessment of a freshwater or marine sample might be biased when using the Microtox bioassay, which has a NaCl-based medium (Villaescusa et al, 1996). This bioassay is known to overestimate the toxicity of metals more than do seawater-based nonmicrobial bioassays (Becerro et al, 1995;Ghosh et al, 1996). This could be because of the difference in speciation (i.e., fewer complexes in the Microtox bioassay medium), but it also could be a result of the inherent sensitivity of Microtox cells to metals.…”
Section: Discussionmentioning
confidence: 99%
“…The precipitation mechanisms mentioned above are likely to protect intact microbenthic assemblages. However, when used for short-term toxicity tests, effect levels were not only in the same range as for bacterial single species toxicity tests (Gosh et al 1996) but were also suitable to detect a shift in community tolerance at much lower levels of long-term zinc exposure. It can be concluded that an in situ concentration of about 1 µM zinc represents a threshold level.…”
Section: Bacterial Thymidine Incorporationmentioning
confidence: 99%
“…The toxicological studies need for simple, inexpensive, rapid and sensitive test in order to screen an increasing number of chemicals and assess their acute and chronic effects (Fargasová, 1994;Ghosh et al, 1996;Radix et al, 2000). Bacteria are considered test organisms that offer good response to these necessity (Ghosh et al 1996).…”
Section: Afb 1 Effects On Vibrio Fischerimentioning
confidence: 99%