2012
DOI: 10.1007/s11547-012-0797-7
|View full text |Cite
|
Sign up to set email alerts
|

Tracking target position variability using intraprostatic fiducial markers and electronic portal imaging in prostate cancer radiotherapy

Abstract: Prostate positional variability during a course of radiation treatment is strongly influenced by setup and organ motion. Organ tracking through fiducial markers and electronic portal imaging is able to reduce the spread of displacements, significantly contributing to improve the ballistic precision of radiation delivery.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 26 publications
1
9
0
Order By: Relevance
“…Direct imaging of the prostate gland and daily verification of its position during each treatment session is essential for reducing the margins and, consequently, avoiding the organs at risk such as rectum and bladder. Several image guidance methods have been investigated in recent years, including tumor tracking with intraprostatic fiducial markers, cone‐beam computed tomography (CBCT), and ultrasound‐based imaging (US‐image guidance) 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 . Ultrasound‐based systems are volumetric and offer better soft‐tissue visualization compared to CBCT, without additional exposure to ionizing radiations (9) .…”
Section: Introductionmentioning
confidence: 99%
“…Direct imaging of the prostate gland and daily verification of its position during each treatment session is essential for reducing the margins and, consequently, avoiding the organs at risk such as rectum and bladder. Several image guidance methods have been investigated in recent years, including tumor tracking with intraprostatic fiducial markers, cone‐beam computed tomography (CBCT), and ultrasound‐based imaging (US‐image guidance) 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 . Ultrasound‐based systems are volumetric and offer better soft‐tissue visualization compared to CBCT, without additional exposure to ionizing radiations (9) .…”
Section: Introductionmentioning
confidence: 99%
“…In this context, correct and precise identification of both target volumes and critical structures are mandatory for accuracy and reliability of dose calculation (11). Several methods have been shown to provide a potential tool to deal with the issue of a poorly visualized anatomical region, with a tight dependence on the type of equipment available (12). Megavoltage CT used for planning purposes is able to consistently reduce image streaks, but requires intraprostatic fiducial marker implantation to enhance organ delineation (2).…”
Section: Discussionmentioning
confidence: 99%
“…Robotic arm SBRT utilizes gold fiducial makers for image guidance, which can limit its use in people who are unwilling to undergo a procedure to place the fiducials 49. Gantry SBRT can utilize severe different imaging-guidance modalities, including cone-beam computed tomography (CT),50 radiofrequency transponders (eg, Calypso ® ),51 CT on rails,52 or gold fiducial markers 49…”
Section: Theoretical Benefits Of Robotic Arm Vs Gantry Sbrtmentioning
confidence: 99%