Transient performance of substation structures and associated grounding systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
28
1
6

Year Published

2009
2009
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(40 citation statements)
references
References 14 publications
5
28
1
6
Order By: Relevance
“…It is also noted from Figures 4a-4d and for all other voltage and current signals that the current traces for all configurations are found to lag the voltage. Similar lagging current trace can also be found in literature [2][3][4][5][6][7] which could be due to inductive effects and ionisation of the earthing systems, which can be prominent under high frequency and high impulse conditions. When taking the earth resistance values under high impulse conditions, the inductive effect is being eliminated in the measurements.…”
Section: A Low Magnitude Currents and At Low Frequency Earth Resistisupporting
confidence: 77%
See 2 more Smart Citations
“…It is also noted from Figures 4a-4d and for all other voltage and current signals that the current traces for all configurations are found to lag the voltage. Similar lagging current trace can also be found in literature [2][3][4][5][6][7] which could be due to inductive effects and ionisation of the earthing systems, which can be prominent under high frequency and high impulse conditions. When taking the earth resistance values under high impulse conditions, the inductive effect is being eliminated in the measurements.…”
Section: A Low Magnitude Currents and At Low Frequency Earth Resistisupporting
confidence: 77%
“…Since the complete ionisation or breakdown is not yet reached in the soil in these tests, the inductive effects would be expected to be present in parallel with the non-linear earth resistances of earthing systems as suggested in previous publications [5,[42][43]. However, it would be expected that at much higher voltages, where the breakdown in soil is expected to occur, the earthing systems are represented as a very low-resistance, as highlighted in many studies before [1][2][3][4][5][6][7]. These equivalent circuits can be seen in Refs.…”
Section: B High Impulse Currents Testsmentioning
confidence: 73%
See 1 more Smart Citation
“…A previous work [47] presented an analysis of lighting current distribution in transmission overhead electrical line towers and ground wires, investigating in particular the effects of stroke-current waveshape on the crest-current magnitudes distribution. In Reference [48] the authors describe the frequency and time domain performance of an electrical substation ground electrode injected by a lightning stroke. Advanced computational models were implemented to simulate the response of grounding electrodes subject to lightning currents.…”