2018
DOI: 10.1109/tsg.2016.2623302
|View full text |Cite
|
Sign up to set email alerts
|

Transmission Grid Secondary Voltage Control Method Using PMU Data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0
1

Year Published

2019
2019
2025
2025

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(22 citation statements)
references
References 31 publications
0
21
0
1
Order By: Relevance
“…The nonlinear equality constraint can be linearized using linearized model of decoupled power flow equations where real power changes are assumed to be less sensitive to changes in the voltage magnitude. Thus, the approximate model of the small disturbance voltage-VAR control can be represented by a linear relation between the reactive power and the voltages of the generator, capacitor and load buses as given in (15) [9,10]. ΔΔ…”
Section: Load Busmentioning
confidence: 99%
See 2 more Smart Citations
“…The nonlinear equality constraint can be linearized using linearized model of decoupled power flow equations where real power changes are assumed to be less sensitive to changes in the voltage magnitude. Thus, the approximate model of the small disturbance voltage-VAR control can be represented by a linear relation between the reactive power and the voltages of the generator, capacitor and load buses as given in (15) [9,10]. ΔΔ…”
Section: Load Busmentioning
confidence: 99%
“…Once the predefined value of tolerance is achieved, the proposed algorithm will stop and produce the optimal u*. (27) where l is the total number of load buses.…”
Section: Load Busmentioning
confidence: 99%
See 1 more Smart Citation
“…Outro controle secundário de tensãoé elaborado por Su et al (2018) utilizando um método adaptativo baseado em "Phasor Measurement Unit" (PMU), unidade de medição fasorial. As perturbações de carga são estimadas online e o objetivoé melhorar os perfis de tensão por meio da diminuição do desvio de tensão da carga.…”
Section: Introductionunclassified
“…An inter-plant voltage control was introduced for improving the voltage stability margin by coordinating reactive power reserves [12]. However, such solutions often lay on on-line (i.e., at each control sampling time) optimization of multi-variable quadratic function which is difficult to implement in real-time, especially when a lot of distant (PMU) measures have to be used [13]. Moreover, voltage and reactive power tracking objectives are mixed into a quadratic index to be minimized and this leads to uncertain reactive power alignment.…”
Section: Introductionmentioning
confidence: 99%