2022
DOI: 10.1109/jsen.2021.3135872
|View full text |Cite
|
Sign up to set email alerts
|

Transparent Flexible Piezoelectric Ultrasound Transducer for Photoacoustic Imaging System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…At present, there are three main methods to fabricate the core flexible active materials for flexible US transducers. First, fabricating flexible piezoelectric polymers directly to be used as active materials for flexible US transducers [ 25 , 26 ]. Second, attaching rigid piezoelectric material films on flexible substrates to form the active materials with certain flexibility [ 1 , 19 , 27 ].…”
Section: Advances In Functional Materials For Flexible Us Transducersmentioning
confidence: 99%
See 2 more Smart Citations
“…At present, there are three main methods to fabricate the core flexible active materials for flexible US transducers. First, fabricating flexible piezoelectric polymers directly to be used as active materials for flexible US transducers [ 25 , 26 ]. Second, attaching rigid piezoelectric material films on flexible substrates to form the active materials with certain flexibility [ 1 , 19 , 27 ].…”
Section: Advances In Functional Materials For Flexible Us Transducersmentioning
confidence: 99%
“…The PAI system with a flexible CMUT array showed an SNR of 46 dB with an axial and lateral resolution of 382 μm and 293 μm, respectively [ 15 ]. Liu et al used a single-element US transducer with a 6.7 MHz center frequency and 86.3% −3 dB fractional bandwidth in a PAI system, as shown in Figure 9 c [ 26 ]. The PAI system with a flexible US transducer also showed the capability and quality of evaluating the imaging depth and 3D imaging, which could image a 2 mm beam from a distance of 36 mm with a 0.94% error in the axial position and 1.66% in the lateral.…”
Section: Practical Imaging Applications With Flexible Us Transducersmentioning
confidence: 99%
See 1 more Smart Citation
“…Fabricating sensors on transparent substrates is another important theme. 74 77 Transparent sensors enable co-axial or trans-illumination optical delivery, which is critical for some implementations such as handheld probes. They also facilitate multimodal imaging, allowing for flexible ultrasound detector integration with other optical modalities.…”
Section: Pa Plus Advanced Ultrasound Sensorsmentioning
confidence: 99%