Treatment of hypotension in pigs with an inspiratory impedance threshold device: A feasibility study

Abstract: These studies demonstrate that it is feasible to use a device that creates inspiratory impedance in spontaneously breathing normotensive and hypotensive pigs to increase blood pressure and enhance cardiopulmonary circulation in the absence of immediate fluid resuscitation. Further studies are needed to evaluate the potential long-term effects and limitations of this new approach to treat hypovolemic hypotension.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
34
1
3

Year Published

2007
2007
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 49 publications
(40 citation statements)
references
References 15 publications
2
34
1
3
Order By: Relevance
“…During ITD breathing there are three key effects associated with central hemodynamics; a decrease in intrathoracic pressure (26), an increase in arterial pressure oscillations (Table 2), and the protection of Q (8,9). At the cerebral level, there are similar decreases in ICP (40), and we have now presented evidence in this investigation to indicate increases in CBFV oscillations (Table 2).…”
Section: Discussionsupporting
confidence: 59%
See 3 more Smart Citations
“…During ITD breathing there are three key effects associated with central hemodynamics; a decrease in intrathoracic pressure (26), an increase in arterial pressure oscillations (Table 2), and the protection of Q (8,9). At the cerebral level, there are similar decreases in ICP (40), and we have now presented evidence in this investigation to indicate increases in CBFV oscillations (Table 2).…”
Section: Discussionsupporting
confidence: 59%
“…The ITD is a small, light-weight, disposable plastic valve that was recently developed for treatment of a number of different clinical conditions associated with significant life-threatening hypotension (24,26,32,33,38). The ITD includes a specially designed valve that closes when the pressure within the thorax is less than atmospheric pressure and a second valve (termed the safety check valve) that opens at a preset negative intrathoracic pressure.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…13 Animal studies had previously demonstrated that an ITD increased mean arterial pressure in heat stroke, 23 and blood pressure, 24 cardiac output, 25 and survival time 26 after hypotension induced by severe blood loss. To determine if there were similar effects in humans, healthy subjects were exposed to progressive lower-body negative pressure.…”
Section: Patient Tolerance and Response To Acute Central Hypovolemia mentioning
confidence: 99%