2006
DOI: 10.1117/12.679497
|View full text |Cite
|
Sign up to set email alerts
|

Trends in synchrotron-based tomographic imaging: the SLS experience

Abstract: Synchrotron-based X-ray Tomographic Microscopy (SRXTM) is nowadays a powerful technique for non-destructive, high-resolution investigations of a broad kind of materials. High-brilliance and high-coherence third generation synchrotron radiation facilities allow micrometer and sub-micrometer, quantitative, three-dimensional imaging within very short time and extend the traditional absorption imaging technique to edge-enhanced and phase-sensitive measurements. At the Swiss Light Source TOMCAT, a new beamline for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
247
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 308 publications
(257 citation statements)
references
References 31 publications
1
247
0
Order By: Relevance
“…Three to six samples of each timepoint were scanned at the Material Science-or TOMCAT-beamline, respectively, of the Swiss Light Source (SLS) of the Paul Scherrer Institut (PSI), Villigen, Switzerland (Stampanoni et al, 2002(Stampanoni et al, , 2006. The energy was tuned to 12.398 keV (corresponding to an X-ray wavelength of 1 Å).…”
Section: Synchrotron Radiation X-ray Tomographic Microscopy and Visuamentioning
confidence: 99%
“…Three to six samples of each timepoint were scanned at the Material Science-or TOMCAT-beamline, respectively, of the Swiss Light Source (SLS) of the Paul Scherrer Institut (PSI), Villigen, Switzerland (Stampanoni et al, 2002(Stampanoni et al, , 2006. The energy was tuned to 12.398 keV (corresponding to an X-ray wavelength of 1 Å).…”
Section: Synchrotron Radiation X-ray Tomographic Microscopy and Visuamentioning
confidence: 99%
“…These are mounted on the synchrotronsource tomography beam line (TOMCAT) [18] and heated by lasers [19] at ∼5 K min −1 to isothermal temperatures T 0 above the glass transition interval T g , yielding highviscosity droplets; experiments at different T 0 yield different viscosities. The glass beads do not lose mass, and do not show liquid-liquid immiscibility or crystallize on the experimental time scales or at the temperatures tested, which has been confirmed previously by differential scanning calorimetry and thermogravimetry [2].…”
Section: Methodsmentioning
confidence: 99%
“…The validity of the proposed technique was demonstrated with experimental measurements performed at the TOMCAT beam line [24], Swiss Light Source, Switzerland. The experimental setup is summarized in Fig.…”
mentioning
confidence: 98%