Tri-Channel Electrochemical Immunobiosensor for Combined Detections of Multiple Exosome Biomarkers of Lung Cancer

Abstract: Current methods for the early diagnosis of cancer can be invasive and costly. In recent years, exosomes have been recognized as potential biomarkers for cancer diagnostics. The common methods for quantitative detection of exosomes, such as nanoparticle tracking analysis (NTA) and flow cytometry, rely on large-scale instruments and complex operation, with results not specific for cancer. Herein, we present a tri-channel electrochemical immunobiosensor for enzyme-free and label-free detecting carcino-embryonic a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…The plasma samples were centrifuged at 10000 g for 30 min to remove cells, cell fragments, and large vesicles and then diluted with PBS buffer. Transmission electron microscopy (TEM) and nanoparticle tracking analysis (NTA) were applied to characterize the morphology and concentration of the exosomes, respectively, and the detail can be found in our previous work [ 59 ].…”
Section: Methodsmentioning
confidence: 99%
“…The plasma samples were centrifuged at 10000 g for 30 min to remove cells, cell fragments, and large vesicles and then diluted with PBS buffer. Transmission electron microscopy (TEM) and nanoparticle tracking analysis (NTA) were applied to characterize the morphology and concentration of the exosomes, respectively, and the detail can be found in our previous work [ 59 ].…”
Section: Methodsmentioning
confidence: 99%
“…Repeatability assessment involved testing the analytical response of each sensor a minimum of three times within a single day. 34,35 The storage period for the assessment of sensor system stability was 24 hours, conducted under optimal storage conditions with the temperature maintained between 4 and 5 °C. Furthermore, the immunosensor's performance was evaluated by computing the relative variation of R CT (DR CT ) using the following equation.…”
Section: Impedimetric Characterization Of Denv Biodetectionmentioning
confidence: 99%
“…An electrochemical biosensor is a device that detects biomarkers by converting molecular interactions into electronic readout signals [ 85 , 86 ]. They have been widely used for EV detection [ 87 , 88 , 89 , 90 , 91 , 92 , 93 ]. Nanomaterials have been used in electrochemical detection systems to improve the signal readout [ 94 , 95 , 96 ].…”
Section: Plasmonic Nanostructuresmentioning
confidence: 99%