2020
DOI: 10.1016/j.saa.2020.118155
|View full text |Cite
|
Sign up to set email alerts
|

Tricolor dual sensor for ratiometrically analyzing potassium ions and dissolved oxygen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 40 publications
0
9
0
Order By: Relevance
“…To investigate cytoplasmic K + dynamics in growing root hairs with high spatial and temporal resolution, a newly developed highly selective K + fluorescent sensor, NK3, was used in this study ( Figure S1 ) [ 17 ]. The optimal NK3 concentration was first determined by treating five-day-old green seedlings of Col-0 with different concentrations of NK3 and imaging under a Zeiss LSM 880 confocal microscope ( Figure S2 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To investigate cytoplasmic K + dynamics in growing root hairs with high spatial and temporal resolution, a newly developed highly selective K + fluorescent sensor, NK3, was used in this study ( Figure S1 ) [ 17 ]. The optimal NK3 concentration was first determined by treating five-day-old green seedlings of Col-0 with different concentrations of NK3 and imaging under a Zeiss LSM 880 confocal microscope ( Figure S2 ).…”
Section: Resultsmentioning
confidence: 99%
“…NK3 is a newly developed small-molecule fluorescent K + sensor ( Figure S1 ) [ 17 ]. The 2 mM stock solutions of NK3 were prepared in DMSO.…”
Section: Methodsmentioning
confidence: 99%
“…The synthesis of the hydroxyl-terminated K + sensor (KS) was given in our previous report. 18 2.2. Instruments.…”
Section: Methodsmentioning
confidence: 99%
“…Challenges for development of well-performed fluorescent K + sensors are mainly from the influence of competing metal ions with comparable ion radius to K + , including Na + , Mg 2+ , Ca 2+ , and so on. Minta and Tsien 3 reported the first commercially available K + sensor PBFI (potassium-binding benzofuran isophthalate) based on benzofuranyl fluorophore and diaza- [18]-crown-6 ether, although it suffered some limitations from the interference of competing Na + . In 2003, He et al 4 constructed a triazacryptand (TAC) platform as the K + recognition unit and successfully overcame the interference of Na + .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation