1997
DOI: 10.1002/(sici)1096-9918(199701)25:1<17::aid-sia206>3.0.co;2-0
|View full text |Cite
|
Sign up to set email alerts
|

True Auger Electron Spectra Measured with a Novel Cylindrical Mirror Analyser (Au, Ag and Cu)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
14
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 1 publication
1
14
0
Order By: Relevance
“…In our previous works we have investigated backscattering electron energy spectra with cascade secondary electrons included [25,26]; the relative intensity calculated agrees excellently well with the experimental N(E) curve of backscattering background of Auger electron spectroscopy spectra that measured by Goto and coworkers with their novel cylindrical mirror analyzer (CMA) [27,28]. It is further shown that both the simulated absolute secondary electron yields for several metals and the relative yield curve for about twenty metals −187− Journal of Surface Analysis Vol.…”
Section: Introductionsupporting
confidence: 75%
“…In our previous works we have investigated backscattering electron energy spectra with cascade secondary electrons included [25,26]; the relative intensity calculated agrees excellently well with the experimental N(E) curve of backscattering background of Auger electron spectroscopy spectra that measured by Goto and coworkers with their novel cylindrical mirror analyzer (CMA) [27,28]. It is further shown that both the simulated absolute secondary electron yields for several metals and the relative yield curve for about twenty metals −187− Journal of Surface Analysis Vol.…”
Section: Introductionsupporting
confidence: 75%
“…To verify theoretical modeling, we shall compare the calculated energy distribution with accurate experimental spectrum. The experimental data were measured by Goto et al in the EN ( E ) mode with a cylindrical mirror analyzer (CMA) equipped with a coaxial electron gun, which is normal to surface; the detected electrons enter the CMA at the polar angle of 42.3 ∘ ± 6 ∘ . To compare with the experimental results, we only count those emitted electrons into the corresponding CMA solid angles of detection.…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, for the accurate experiment measurement of electron spectrum, Goto et al have developed a novel cylindrical mirror analyzer (CMA) system equipped with a coaxial electron gun; by eliminating many experimental error sources the standard EN ( E ) spectra have been measured for many materials in full energy range and down to very low primary energies . Such spectra data are then ideal for comparison with the simulation result in order to test the validity of the physical model.…”
Section: Introductionmentioning
confidence: 99%
“…16 The relation between the redistributed SE energy and the tertiary-electron emission yield is identical to that between the primary-electron energy and the SE emission yield. 16 The relation between the redistributed SE energy and the tertiary-electron emission yield is identical to that between the primary-electron energy and the SE emission yield.…”
Section: Secondary-electron Redistribution and Image Contrastmentioning
confidence: 78%