2013
DOI: 10.1053/j.ajkd.2013.03.030
|View full text |Cite
|
Sign up to set email alerts
|

Tubular Secretion of Creatinine in Autosomal Dominant Polycystic Kidney Disease: Consequences for Cross-sectional and Longitudinal Performance of Kidney Function Estimating Equations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
17
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(18 citation statements)
references
References 27 publications
1
17
0
Order By: Relevance
“…However, serial measurement of kidney function in 300 patients with ADPKD in 4 different centers is not feasible, and it recently has been shown that measured GFR and eGFR in ADPKD are highly correlated. 58 Finally, in this study, total kidney volume will be measured using MRI, a method that is well validated. 4,14 …”
Section: Discussionmentioning
confidence: 99%
“…However, serial measurement of kidney function in 300 patients with ADPKD in 4 different centers is not feasible, and it recently has been shown that measured GFR and eGFR in ADPKD are highly correlated. 58 Finally, in this study, total kidney volume will be measured using MRI, a method that is well validated. 4,14 …”
Section: Discussionmentioning
confidence: 99%
“…In ADPKD patients at high measured GFR (>105 ml/min/1.73m 2 ), tubular secretion of creatinine has been shown to be significantly greater than in healthy controls with the same renal function, thus contributing to a lower plasma creatinine level at those early stages of the disease[16]. Nowadays CKD-EPI equation has been shown to be the most precise equation to estimate GFR especially for those with eGFR values >60ml/min/1.73m2[17].…”
Section: Discussionmentioning
confidence: 99%
“…Here we compare the performance of measured (mGFR) and eGFR in the Consortium for Renal Imaging Studies of PKD (CRISP) 57 , a prospective study of 241 patients, 15–45 year-old, with an initial creatinine clearance >70 mL/min, and measurements of height adjusted total kidney volume (HtTKV), mGFR by the iothalamate clearance 5 and serum creatinine yearly during four years and biennially thereafter 8 . To adjust for calibration bias, serum samples were exchanged between the four study sites and the Cleveland Clinic Laboratory and calibration equations were derived for each site.…”
mentioning
confidence: 99%
“…Four studies have measured the bias, precision and accuracy of eGFR compared to mGFR in ADPKD 4,8,10 (Supplemental Table 3). In general the bias of eGFR is greater and the accuracy less when the mGFR values are high.…”
mentioning
confidence: 99%
See 1 more Smart Citation