2022
DOI: 10.1016/j.corsci.2022.110346
|View full text |Cite
|
Sign up to set email alerts
|

Tuning the pitting performance of a Cr-13 type martensitic stainless steel by tempering time

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 37 publications
(11 citation statements)
references
References 73 publications
1
8
0
Order By: Relevance
“…Abreu et al [42] also pointed out that the low-frequency time constant should be associated with the passive lm on AISI 316 and 304 SS, as the CPE parameter (Q) in high-frequency remained almost constant with the decreasing of lm thickness by prolonging the immersion time (otherwise it could be increased as lm thickness decreased). In our previous work, the low-frequency time constant was also attributed to the passive lm of the Cr-13 type MSS that had been tempered at 500°C for 2-24 h, of which the EIS Bode plot exhibited the same feature as the X818-LC coating in the current work [40] . Therefore, based on the tting results of the current work, the low-and high-frequency time constant of X818-LC sample are attributed to the passive lm and the charge transfer reaction on steel substrate/solution dl, respectively.…”
Section: Electrochemical Performancesupporting
confidence: 58%
See 4 more Smart Citations
“…Abreu et al [42] also pointed out that the low-frequency time constant should be associated with the passive lm on AISI 316 and 304 SS, as the CPE parameter (Q) in high-frequency remained almost constant with the decreasing of lm thickness by prolonging the immersion time (otherwise it could be increased as lm thickness decreased). In our previous work, the low-frequency time constant was also attributed to the passive lm of the Cr-13 type MSS that had been tempered at 500°C for 2-24 h, of which the EIS Bode plot exhibited the same feature as the X818-LC coating in the current work [40] . Therefore, based on the tting results of the current work, the low-and high-frequency time constant of X818-LC sample are attributed to the passive lm and the charge transfer reaction on steel substrate/solution dl, respectively.…”
Section: Electrochemical Performancesupporting
confidence: 58%
“…In our previous work, the low-frequency time constant was also attributed to the passive film of the Cr-13 type MSS that had been tempered at 500 °C for 2-24 h, of which the EIS Bode plot exhibited the same feature as the X818-LC coating in the current work. 36 Therefore, based on the fitting results of the current work, the low-and medium-frequency time constant of X818-LC sample are attributed to the passive film and the charge transfer reaction on steel substrate/ solution dl, respectively. Hence, the electrochemical elements displayed in Fig.…”
Section: Results and Analysesmentioning
confidence: 69%
See 3 more Smart Citations