Two-channel IR gas sensor with two detectors based on LiTaO3 single-crystal wafer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…With provided 0.15Mean Spherical Candela Power (MSCP) radiation intensity of IR filament, signal estimation was estimated for emitted light intensity value for reference channel (0.52W) as well as at CO2 channel (0.35W). Ray tracing analysis was carried out in ZEMAX for various gas cell design geometries to identify the reflection loss and availability of signal at detector end [2] . Ray tracing analysis was carried out considering numbers of reflections from inside the walls, the total path length of light to travel from source end to detector end, and the incidence angle at the detector for every single ray hitting the detector [3] .…”
Section: Conceptualization / Methodologymentioning
confidence: 99%
“…With provided 0.15Mean Spherical Candela Power (MSCP) radiation intensity of IR filament, signal estimation was estimated for emitted light intensity value for reference channel (0.52W) as well as at CO2 channel (0.35W). Ray tracing analysis was carried out in ZEMAX for various gas cell design geometries to identify the reflection loss and availability of signal at detector end [2] . Ray tracing analysis was carried out considering numbers of reflections from inside the walls, the total path length of light to travel from source end to detector end, and the incidence angle at the detector for every single ray hitting the detector [3] .…”
Section: Conceptualization / Methodologymentioning
confidence: 99%
“…The lower detection level of the system (3% in air) can be further improved by using high power laser, increasing the detection area (increasing lasing spot size), and multiple path gas detection by mirror arrangement Jun et al, 2011;Massie et al, 2006;Wendong et al, 2010) etc if the measurement environment warrants. It is evident from the results that the proposed system can detect methane at lower concentrations (3%) than the explosion level (5%).…”
Section: Sensor Response and Methane Concentrationmentioning
confidence: 99%