Two new automated, compared with two enzyme-linked immunosorbent, antimüllerian hormone assays

Abstract: 3 Capsule:The new automated AMH assays provide values that are substantially lower than existing AMH ELISAs. Assay specific interpretation is necessary with international standardization urgently required. Conclusions:The novel automated assays exhibit strong concordance in calibration but derived values are substantially lower than obtained from preexisting assays with assay specific interpretation required for routine clinical use. These results highlight the need for an international AMH standard.5

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
82
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(89 citation statements)
references
References 22 publications
6
82
0
1
Order By: Relevance
“…AMH was measured in the serum of all our cases by the referring physician. The results are not comparable because they were obtained with different methods [Nelson et al, 2015].…”
Section: Endocrine Investigationsmentioning
confidence: 84%
“…AMH was measured in the serum of all our cases by the referring physician. The results are not comparable because they were obtained with different methods [Nelson et al, 2015].…”
Section: Endocrine Investigationsmentioning
confidence: 84%
“…It included a predilution step of the specimen in assay buffer before addition to the ELISA plate, which gave more reliable AMH results [55]. Currently, fully automatic measurements of serum AMH concentrations are also available (Elecsys, AMH, Roche and Access, AMH, Beckman Coulter) [56]. Moreover, new commercial AMH enzyme-linked immunosorbent assay (picoAMH ELISA, AnshLabs) with a lower threshold of detection is useful especially in women with diminished ovarian reserve [57].…”
Section: Amh In Pcos Diagnosismentioning
confidence: 99%
“…W 2013 roku wprowadzono modyfikację do oznaczeń II generacji, która polegała na dodatkowym rozcieńczeniu próbki, co dawało bardziej wiarygodne oznaczenia stężenia AMH w badanym materiale [55]. Obecnie, dostępne są w pełni zautomatyzowane metody do oznaczenia stężeń AMH w materiale biologicznym (Elecsys AMH, Roche oraz Acess, AMH, Beckam Coulter) [56]. Warto podkreślić, że dostępne są również nowe, bardziej czułe zestawy wykorzystujące metodę ELISA (picoAMH ELISA, AnshLabs), które pozwalają na oznaczanie niższych stężeń AMH.…”
Section: Amh W Diagnostyce Pcosunclassified
“…The values derived from the Immunotech Beckman Coulter (IBC) assay and the Gen II Beckman Coulter assay were considered equivalent, as the Gen II assay was calibrated on the IBC assay standards . Similarly, the values from the Ansh lab assay were reported to be similar to the Gen II assay . Where pooling of data was not appropriate, a narrative summary including results from individual studies was presented.…”
Section: Methodsmentioning
confidence: 99%