Sterile Filtration
DOI: 10.1007/b104242
|View full text |Cite
|
Sign up to set email alerts
|

Types of Filtration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 8 publications
0
9
0
1
Order By: Relevance
“…They are stable to heating to 130°C but are sensitive to many solvents. Deep, screened, or mixed retention mechanisms take place in membrane filters, depending on the ratio of pore size to particle size [8]. The rigidity of the support and, thus, the constancy of pore size, and also the mainly sieving mechanism of separation allow membrane filters to be described in terms of some particular pore size [9].…”
Section: Properties and Characteristics Of Materials For Sterilizing mentioning
confidence: 99%
“…They are stable to heating to 130°C but are sensitive to many solvents. Deep, screened, or mixed retention mechanisms take place in membrane filters, depending on the ratio of pore size to particle size [8]. The rigidity of the support and, thus, the constancy of pore size, and also the mainly sieving mechanism of separation allow membrane filters to be described in terms of some particular pore size [9].…”
Section: Properties and Characteristics Of Materials For Sterilizing mentioning
confidence: 99%
“…It is a promising approach for cell sample preparation. However, it should be noticed that in practical application, the cross-flow filter has to be properly evaluated due to performance differences in dead-volume, shear forces , cleanability, pressure conditions, energy inputs, and flow patterns [3]. Hence, improvement should be carried out for the previous cross-flow microfilter.…”
Section: Materials Andfabricationsmentioning
confidence: 99%
“…2. There being the presence of "dead-end" in the flat membrane filters [3], clogging is inevitable to separate the target cell with smaller dimensions.…”
Section: Clogging Failure Of Membrane-based Microfiltermentioning
confidence: 99%
“…Îíè ñòàáèëüíû ïðè íàãðåâàíèè äî 130°C, íî ÷óâñòâèòåëüíû êî ìíîãèì ðàñòâîðèòåëÿì.  ìåìáðàííûõ ôèëüòðàõ îñóùåñòâëÿåòñÿ â çàâèñèìîñòè îò ñîîòíîøåíèÿ ðàçìåðà ïîð è ðàçìåðà ÷àñòèö ãëóáèííûé, ýêðàííûé èëè ñìåøàííûé ìåõàíèçì óäåðaeèâàíèÿ [8]. Âñëåäñòâèå aeåñòêîñòè êàðêàñà è, ñëåäîâàòåëüíî, íåèç-ìåííîñòè ðàçìåðà ïîð, à òàêaeå áëàãîäàðÿ ïðåèìóùåñò-âåííî ñèòîâîìó ìåõàíèçìó ðàçäåëåíèÿ ìåìáðàííîìó ôèëüòðó ìîaeåò áûòü ïðèïèñàí îïðåäåëåííûé ðàçìåð ïîð [9].…”
Section: ñâîéñòâà è õàðàêòåðèñòèêè ìàòåðèàëîâ äëÿ ñòåðèëèçóþùåé ôèëüòunclassified