2014
DOI: 10.1039/c3ay41843j
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-fast microwave-assisted digestion in choline chloride–oxalic acid deep eutectic solvent for determining Cu, Fe, Ni and Zn in marine biological samples

Abstract: This is the first application that incorporates microwave heating with deep eutectic solvent (DES) for dissolution of biological samples.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
18
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(25 citation statements)
references
References 38 publications
2
18
0
2
Order By: Relevance
“…Hence 0.1 g was preferred to be the optimum coal amount in proposed MW-AAE procedure due to highest recoveries (100%) achieved. Similar observations were also reported by Krishna et al [39] and Ghanemi et al [40].…”
Section: Effect Of Sample Amountsupporting
confidence: 82%
“…Hence 0.1 g was preferred to be the optimum coal amount in proposed MW-AAE procedure due to highest recoveries (100%) achieved. Similar observations were also reported by Krishna et al [39] and Ghanemi et al [40].…”
Section: Effect Of Sample Amountsupporting
confidence: 82%
“…The choice of the appropriate solvent is crucial for maximum process utilization, since many solvents, especially non-polar ones (toluene, hexane and dichloromethane), are transparent to microwave energy [135]. On the other hand, polar solvents such as MeOH, EtOH and ethyl acetate absorb the microwave energy, convert it into heat and thus cause the cell wall to break, and the analytes are transferred into the solvent matrix [136,137]. Taking into account that DES/NADES can efficiently absorb microwave energy [138], it is a rather interesting approach to use DES/NADES as solvent or co-solvent in the MAE for the effective extraction of different classes of bioactive compounds.…”
Section: Microwave-assisted Des/nades Extractions Of Bioactive Compoundsmentioning
confidence: 99%
“…Two groups of researchers reported improvements of reference methods in this area. Polyatomic interferences on the measurements of the 42 Ca : 44 Ca and 24 Mg : 26 Mg were substantially resolved at medium resolution, whereas residual interferences on the ratio 39 K : 41 K could not be eliminated completely at levels below 100 ng g À1 even using the high resolution mode. Measurements were carried out by SF-ICP-MS, using 44 Ca, 26 Mg and 41 K for ID.…”
Section: Metrology Interlaboratory Studies Reference Materials and mentioning
confidence: 92%
“…Ghanemi et al 44 proposed for the rst time the microwave-assisted digestion of sh muscle samples with the DES choline chloride-oxalic acid. Ghanemi et al 44 proposed for the rst time the microwave-assisted digestion of sh muscle samples with the DES choline chloride-oxalic acid.…”
Section: Digestion Extraction and Preconcentrationmentioning
confidence: 99%