2017
DOI: 10.1007/s00604-017-2178-3
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive detection of the β-adrenergic agonist brombuterol by a SERS-based lateral flow immunochromatographic assay using flower-like gold-silver core-shell nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(23 citation statements)
references
References 33 publications
0
23
0
Order By: Relevance
“…SERS signals are based on the increase of optical absorption for reporter molecules by orders of magnitude after their immobilization on the surface of nanoparticles. The possibility of such highly sensitive analyses is demonstrated in the works of Sanchez-Purra et al [110], Fu et al [111], and Marks et al [112]. Clarke et al [113] described the combination of SERS registration with rapid vertical flow technology as an additional means of increasing sensitivity.…”
Section: Proper Response For Lfiamentioning
confidence: 99%
“…SERS signals are based on the increase of optical absorption for reporter molecules by orders of magnitude after their immobilization on the surface of nanoparticles. The possibility of such highly sensitive analyses is demonstrated in the works of Sanchez-Purra et al [110], Fu et al [111], and Marks et al [112]. Clarke et al [113] described the combination of SERS registration with rapid vertical flow technology as an additional means of increasing sensitivity.…”
Section: Proper Response For Lfiamentioning
confidence: 99%
“…For these reasons, SERS has been widely used for the detection of a wide range of analytes, from big biomolecules to small inorganic molecules . For the detection of small molecules, as small molecules are too small to combine to antigens, competitive indirect methods were usually used . In the process of ICA‐SERS, all the steps are identical to those of ICA, except that the gold colloid used as labels in ICA also work as the substrate for SERS in ICA‐SERS.…”
Section: Introductionmentioning
confidence: 99%
“…[15,16] For the detection of small molecules, as small molecules are too small to combine to antigens, competitive indirect methods were usually used. [17,18] In the process of ICA-SERS, all the steps are identical to those of ICA, except that the gold colloid used as labels in ICA also work as the substrate for SERS in ICA-SERS. Immunoprobes captured by the coating antigen on the test line of ICA strip can be used to represent the content of analyte and would be measured by SERS for quantitative analysis.…”
Section: Introductionmentioning
confidence: 99%
“…18,19 SERS has gained a lot of attention on account of its non-destructivity, high selectivity, ultrasensitivity, reliability and fast operation in testing chemical and/or biological molecules in trace amounts. 20,21 For SERSbased SAL detection, a principal challenge is the low binding affinity of these phenolic molecules on silver or gold surfaces, 22,23 resulting in poor SERS signals when the analytes are mixed with SERS-active nanoparticles directly (Fig. S1 †).…”
Section: Introductionmentioning
confidence: 99%