Surgical Innovations in Glaucoma 2013
DOI: 10.1007/978-1-4614-8348-9_11
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasonic Circular Cyclocoagulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Investigators from France were the first to report on the efficacy and safety of ultrasonic circular cyclocoagulation (UC3) treatment using HIFU in refractory glaucoma (16, 24, 25).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Investigators from France were the first to report on the efficacy and safety of ultrasonic circular cyclocoagulation (UC3) treatment using HIFU in refractory glaucoma (16, 24, 25).…”
Section: Discussionmentioning
confidence: 99%
“…Other cycloablative techniques like cryotherapy and laser cyclophotocoagulation are much less precise. Endoscopic cyclophotocoagulation (ECP) allows direct visualization of ciliary processes with better focusing, but requires invasive entry into the eye with all the related complications (23)(24)(25).…”
Section: © 2015 Wichtig Publishingmentioning
confidence: 99%
“…Ultrasound has been used for cyclodestruction since the 1980s [ 20 , 44 ]. Transscleral cyclodestruction by means of ultrasound has an important advantage over laser energy; because scleral tissue has significant light-scattering properties, a large amount of laser energy may be needed for clinically meaningful ciliary body ablation.…”
Section: Techniques and Evidence On Efficacymentioning
confidence: 99%
“…Transscleral cyclodestruction by means of ultrasound has an important advantage over laser energy; because scleral tissue has significant light-scattering properties, a large amount of laser energy may be needed for clinically meaningful ciliary body ablation. This excessive laser energy may produce significant damage to collateral tissues such as conjunctiva, sclera and crystalline lens [ 20 , 44 ].…”
Section: Techniques and Evidence On Efficacymentioning
confidence: 99%
“…Unlike reduced aqueous production, an increase in the aqueous outflow via the uveoscleral pathway is perhaps a less expected mechanism of action of UCP that nonetheless has been hypothesised on multiple occasions. 11,12,[21][22][23] Aptel observed in 2014 that a fluid space could be seen between the sclera and the ciliary body, and between the sclera and the choroid adjacent to treated areas, 21,24 and hypothesised that this corresponds to an area where the opening of the space should lead to an increase of the aqueous outflow via the uveoscleral pathway. A more recent prospective, observational monocentric study from Rouland and Aptel, using three-dimensional ultrasound biomicroscopy (UBM) that included 24 eyes from 19 patients, demonstrated that, in addition to reduction in aqueous humour production, UCP treatment caused an increase in aqueous humour outflow due to uveoscleral pathway opening.…”
Section: A: Control; B: Having Undergone Treatment With the Ultrasounmentioning
confidence: 99%