1996
DOI: 10.1056/nejm199603073341001
|View full text |Cite
|
Sign up to set email alerts
|

Uncertain Value of Electronic Fetal Monitoring in Predicting Cerebral Palsy

Abstract: Specific abnormal findings on electronic monitoring of the fetal heart rate were associated with an increased risk of cerebral palsy. However, the false positive rate was extremely high. Since cesarean section is often performed when such abnormalities are noted and is associated with risk to the mother, our findings arouse concern that, if these indications were widely used, many cesarean sections would be performed without benefit and with the potential for harm.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
207
1
7

Year Published

1997
1997
2014
2014

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 487 publications
(219 citation statements)
references
References 31 publications
4
207
1
7
Order By: Relevance
“…This problem indicates the need for a novel method for prenatal diagnosis. 15,16 In the present study, we developed a FMCG by modifying our recently developed 64-channel MCG. 17,18 The special features of MCG make it possible for the device to perform a 3-dimensional analysis of the magnetic fi eld generated by the One-way ANOVA: P = 0.003 phenomenal electric activities of the heart in both fetuses and adults.…”
Section: Discussionmentioning
confidence: 99%
“…This problem indicates the need for a novel method for prenatal diagnosis. 15,16 In the present study, we developed a FMCG by modifying our recently developed 64-channel MCG. 17,18 The special features of MCG make it possible for the device to perform a 3-dimensional analysis of the magnetic fi eld generated by the One-way ANOVA: P = 0.003 phenomenal electric activities of the heart in both fetuses and adults.…”
Section: Discussionmentioning
confidence: 99%
“…Conversely, its low specificity justifies efforts to develop additional tests to help identifying false-positive tests of FHR visual analysis. 1,2 Complementary methods, such as fetal scalp pH and lactates, fetal electrocardiogram (ECG) ST segment analysis, and T/QRS ratio (STAN 1 ; Neoventa Medical, Moelndal, Sweden), have been shown, at the best, to modestly reduce fetal metabolic acidosis and rate of operative deliveries. [3][4][5][6] As FHR with reduced or absent variability is one of the most significant parameters to predict the development of fetal acidosis, 2,7 some researches focused on FHR variability analysis.…”
mentioning
confidence: 99%
“…Thus, our findings are consistent with the earlier studies suggesting high false-positive rate of CTG, making it a poor tool in predicting the outcome of asphyxiated children. 7,11,29 Several serum, urine or cerebrospinal fluid biomarkers have been examined as markers of outcome in HIE, but none has been studied extensively enough to warrant routine clinical use. 31 In this study, there was likewise no correlation between the blood biomarkers according to the outcome in the asphyxiated.…”
Section: Discussionmentioning
confidence: 99%
“…CTG has a high sensitivity but low specificity for fetal hypoxia or asphyxia. 11 Increased cerebral blood flow velocity (CBFV) and resistive index reduced below 0.55 by pulsed Doppler ultrasonography, have been associated with poor outcome in birth asphyxia assessed at the age from 24 to 72 h. [12][13][14] We have previously shown a strong association of increased systolic CBFV in the anterior cerebral (ACA) or in the basilar (BA) arteries at around 24 h of age with adverse neurological outcome at the age of 1 year, whereas reduced resistive index failed to show association with poor outcome (submitted/unpublished data). In this study, we sought to analyse the obstetric parameters, biochemical asphyxia markers, HIE symptoms or their combinations, in predicting the neurological outcome at 1 year in full-term asphyxiated infants.…”
Section: Introductionmentioning
confidence: 99%