2021
DOI: 10.1021/acsomega.1c04957
|View full text |Cite|
|
Sign up to set email alerts
|

Uniform Mass Sensitivity Distribution of Elliptically Designed Electrodes Based on a Quartz Crystal Microbalance

Abstract: Uniformization of mass sensitivity distribution is conducive to the application of the quartz crystal microbalance (QCM) in some fields. However, the sensitivity of the QCM sensor surface perpendicular to the displacement direction is higher that of the displacement direction in the mass sensitivity distribution of ring and double-ring QCMs, which leads to poor reproducibility of the sensor. Considering the effect of the electrode structure on the mass sensitivity distribution, we found that for ring- and doub… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…Based on Gao et al, other additional configurations of electrode shapes have been designed to obtain uniform mass sensitivity distribution [ 49 , 51 , 52 , 53 ]. For example, Jiang et al used mathematical models and the finite element method (FEM) to further analyze in depth the mass sensitivity function distribution of the double-ring electrode QCM [ 52 ].…”
Section: Electrode Shape and Mass Sensitivitymentioning
confidence: 99%
See 2 more Smart Citations
“…Based on Gao et al, other additional configurations of electrode shapes have been designed to obtain uniform mass sensitivity distribution [ 49 , 51 , 52 , 53 ]. For example, Jiang et al used mathematical models and the finite element method (FEM) to further analyze in depth the mass sensitivity function distribution of the double-ring electrode QCM [ 52 ].…”
Section: Electrode Shape and Mass Sensitivitymentioning
confidence: 99%
“…In addition, there exists an optimal electrode outer radius with a more uniform displacement distribution for the double-ring electrode QCM. Soon after, they continued to investigate the distribution of the uniform mass sensitivity function of the ellipsoidal electrode QCM, as shown in Figure 5 [ 53 ]. Their results show that in order to achieve the uniformity of the mass sensitivity of the elliptical ring electrode QCM, it is recommended that the ratio of the short axis to the long axis of the elliptical ring electrode should be 0.8.…”
Section: Electrode Shape and Mass Sensitivitymentioning
confidence: 99%
See 1 more Smart Citation