“…Here we suggest the use of temperature-responsive “self-extinguishing” microcapsules to achieve highly reliable safety of the cell and also maintain the desired electrochemical performance. Accelerating rate calorimetry (ARC) studies on LIBs have demonstrated that significant exothermic heat, which is produced by decomposition of the electrolyte and active material, accelerates thermal runaway through violent combustion reactions. − Upon this background, we successfully incorporated a commonly used extinguishing agent (1,1,1,2,2,3,4,5,5,5-decafluoro-3-methoxy-4-(trifluoromethyl)-pentane) (DMTP)) with remarkable endothermic properties (Δ H = +102.1 J g –1 ) , in an LIB to effectively suppress a drastic temperature rise. The extinguishing agent can be vaporized in a timely manner by the absorption of external heat and finally extinguishes the fire before the cell reaches a serious thermal runaway state.…”