2021
DOI: 10.1109/jstqe.2021.3049689
|View full text |Cite
|
Sign up to set email alerts
|

Upconversion-Linked Immunoassay for the Diagnosis of Honeybee Disease American Foulbrood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 42 publications
0
3
0
Order By: Relevance
“…The suspension was purged for 40 min with argon and then dialyzed in a Float-A-Lyzer G2 dialysis device (100 kDa M W cut-off) against 4 L of dialysis buffer (50 × 10 −3 m Tris, 0.05% NaN 3 , 1 × 10 −3 m KF, pH 7.5 at 4°C for 72 h), which was exchanged nine times. [32]…”
Section: Sa-peg-ucnp Conjugatesmentioning
confidence: 99%
“…The suspension was purged for 40 min with argon and then dialyzed in a Float-A-Lyzer G2 dialysis device (100 kDa M W cut-off) against 4 L of dialysis buffer (50 × 10 −3 m Tris, 0.05% NaN 3 , 1 × 10 −3 m KF, pH 7.5 at 4°C for 72 h), which was exchanged nine times. [32]…”
Section: Sa-peg-ucnp Conjugatesmentioning
confidence: 99%
“…To further assess the performance of the UCNP-based dot-blot, we compared the results with MTP-based assays (Table and Figure S10), which were carried out according to our previously published protocols. ,, The achieved LODs in the real samples were 125 pg/mL of HSA in 25% urine, 2.5 pg/mL of PSA in 50% serum, and 39 pg/mL of cTn in 25% serum. In all cases, the dot-blot assays resulted in LODs that were 1 order of magnitude higher as compared with MTP assays.…”
Section: Resultsmentioning
confidence: 99%
“…It faces intrinsic shortages of low sensitivity and temporary readout. [ 38 ] Fortunately, UCNPs with high photostability and free background can well overcome these problems. ULISA, short for upconversion‐linked immunosorbent assay, has been developed by replacing enzymes with UCNP phosphors in the labeling process.…”
Section: Strategies For Upconversion Nanoparticle‐based Bacteria Dete...mentioning
confidence: 99%
“…The ULISA showed low cross‐reactivity and achieved LOD of 2.9 × 10 3 CFU mL −1 , a 22‐fold improvement compared to the ELISA performed under the same conditions. [ 38 ] It follows that the sensitivity of ULISA is ≈1–3 orders of magnitude higher than that of ELISA, representing more potential in early diagnosis of bacterial infection. In addition, the absorbance should be immediately recorded after stopping the enzymatic reaction in an ELISA protocol, while the luminescent readout in ULISA is stable and can be measured without time constraint.…”
Section: Strategies For Upconversion Nanoparticle‐based Bacteria Dete...mentioning
confidence: 99%