2012
DOI: 10.1016/j.jmr.2011.11.004
|View full text |Cite
|
Sign up to set email alerts
|

Use of Carr–Purcell pulse sequence with low refocusing flip angle to measure T1 and T2 in a single experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0
7

Year Published

2012
2012
2019
2019

Publication Types

Select...
5
2

Relationship

4
3

Authors

Journals

citations
Cited by 19 publications
(25 citation statements)
references
References 12 publications
0
18
0
7
Order By: Relevance
“…During the TD‐NMR real‐time monitoring, the polymerization reactions were conducted at 27 °C (probe air flow temperature controller, ±0.01 °C resolution) in NMR glass tubes (18 mm outer diameter) containing the reaction mixture and sealed with silicone septa. The tubes were inserted into the spectrometer (Maran Ultra 0.54 T) probe, where the monitoring was performed by the use of Carr−Purcell CWFP (CP‐CWFP) normalRDbold−()π2bold−τbold−π2echoπ2n …”
Section: Methodsmentioning
confidence: 99%
“…During the TD‐NMR real‐time monitoring, the polymerization reactions were conducted at 27 °C (probe air flow temperature controller, ±0.01 °C resolution) in NMR glass tubes (18 mm outer diameter) containing the reaction mixture and sealed with silicone septa. The tubes were inserted into the spectrometer (Maran Ultra 0.54 T) probe, where the monitoring was performed by the use of Carr−Purcell CWFP (CP‐CWFP) normalRDbold−()π2bold−τbold−π2echoπ2n …”
Section: Methodsmentioning
confidence: 99%
“…De Andrade et al 72 analyzed the Carr-Purcell pulse sequence (originally 901-t-1801-t-echo) with a low refocusing flip angle replacing the 1801 pulse. Different limits were investigated and it was concluded that the sequence could, under certain condition, be used to measure T 1 and T 2 in a single scan.…”
Section: Experimental Aspectsmentioning
confidence: 99%
“…39 Andrade et al desenvolveram um novo método para medidas de qualidade de sementes oleaginosas online, baseado na dependência de T 1 e T 2 . 40 Esse método foi denominado CP-CWFP por ser baseado na sequência de eco de spin proposta por Carr-Purcell (CP) e, ainda, por possuir características semelhantes ao método CWFP. A sequência CP-CWFP é mais eficiente do que a CWFP para medida dos tempos de relaxação quando T 1 ~ T 2 .…”
Section: (4)unclassified
“…A sequência CP-CWFP é mais eficiente do que a CWFP para medida dos tempos de relaxação quando T 1 ~ T 2 . Portanto, esse novo método de medida é mais eficiente para ser usado em espectrômetros de RMN com baixos campos magnéticos (B 0 < 0,5 T ~20 MHz para 1 H), 40 uma vez que nessa condição T 1 e T 2 tendem a possuir valores similares. Portanto, a sequência CP-CWFP é uma técnica mais robusta para análises em espectrômetros de RMN online com ímãs permanentes, que deverão ser os mais utilizados em controle de qualidade de processos industriais.…”
Section: (4)unclassified
See 1 more Smart Citation