1997
DOI: 10.1016/s0021-9673(97)00086-1
|View full text |Cite
|
Sign up to set email alerts
|

Use of ion chromatography for the determination of transition metals in the control of sewage-treatment-plant and related waters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
19
0

Year Published

2000
2000
2019
2019

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 25 publications
1
19
0
Order By: Relevance
“…The system flow was 0.3 mL min −1 through an IonPac CG5A (2 × 50 mm) guard column, CS5A capillary column (2 × 250 mm) and UV-VIS spectrophotometry with detection at 530 nm (Cardellicchio et al, 1997). For soluble Fe(II), Fe(III), Cu, and Zn, the detection limits (USEPA, 1997) were 1.7, 0.4, 1.3, and 4.1 µg L −1 , respectively, and the expanded uncertainties at the 95 % level of confidence (BIPM, 2008) were 3, 42, 46, and 56 %, respectively.…”
Section: Ion Chromatography Analysismentioning
confidence: 99%
“…The system flow was 0.3 mL min −1 through an IonPac CG5A (2 × 50 mm) guard column, CS5A capillary column (2 × 250 mm) and UV-VIS spectrophotometry with detection at 530 nm (Cardellicchio et al, 1997). For soluble Fe(II), Fe(III), Cu, and Zn, the detection limits (USEPA, 1997) were 1.7, 0.4, 1.3, and 4.1 µg L −1 , respectively, and the expanded uncertainties at the 95 % level of confidence (BIPM, 2008) were 3, 42, 46, and 56 %, respectively.…”
Section: Ion Chromatography Analysismentioning
confidence: 99%
“…Thus, the separation of metals with PDCA is based on pure anion exchange. The separation was superior to the oxalic separation and it was possible to separate and determine Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Cd 2+ , Mn 2+ and Fe 2+ in one injection [4]. Unfortunately, Pb 2+ could not be detected by the post-column reagent PAR because not only was it strongly complexed by PDCA but it also exhibited slow complexation/decomposition kinetics [12].…”
Section: Chromatographic Separationmentioning
confidence: 99%
“…However, the Pb 2+ -PDCA complex was so strong that Pb 2+ could not be detected simultaneously with other heavy and transition metals [4], but this could be improved by using 5-Br-PADAP instead of PAR as the post-column chromogenic reagent. 5-Br-PADAP could form stable complexes with metals.…”
Section: Effects Of 5-br-padap Concentration On Peak Heights Of Metalsmentioning
confidence: 99%
See 1 more Smart Citation
“…Nowadays, stationary phases having both cation and anion exchange capacities are found to be more useful in separating heavy and transition metal ions [29] because the separation is controlled by the concentrations of free metal ions and the various insitu metal complexes formed, which are in an equilibrium with each other [30]. One such mixed ion exchanger namely Ion Pac CS5A has been widely used for the separation of lanthanides and transition metal cations in several matrices [31][32][33].…”
mentioning
confidence: 99%