2015
DOI: 10.1016/j.radphyschem.2015.04.025
|View full text |Cite
|
Sign up to set email alerts
|

Use of MOSFET dosimeters to validate Monte Carlo radiation treatment calculation in an anthropomorphic phantom

Abstract: Radiation therapy treatment planning based on Monte Carlo simulation provide a very accurate dose calculation compared to deterministic systems. Nowadays, Metal-OxideSemiconductor Field Effect Transistor (MOSFET) dosimeters are increasingly utilized in radiation therapy to verify the received dose by patients.In the present work, we have used the MCNP6 (Monte Carlo N-Particle transport code) to simulate the irradiation of an anthropomorphic phantom (RANDO) with a medical linear accelerator. The detailed model … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…At present however, the literature (Francescon et al 1998, Sauer andWilbert 2007) does not generally support the use of commercial MOSFETs for small-field dosimetry in megavoltage photon beams because of the high spread of their data (IAEA 2017). MOSFETs have also been used to verify dose in IMRT dose verification (Chuang et al 2002), and to validate a Monte Carlo-based TPS (Juste et al 2015).…”
Section: Applicationsmentioning
confidence: 99%
“…At present however, the literature (Francescon et al 1998, Sauer andWilbert 2007) does not generally support the use of commercial MOSFETs for small-field dosimetry in megavoltage photon beams because of the high spread of their data (IAEA 2017). MOSFETs have also been used to verify dose in IMRT dose verification (Chuang et al 2002), and to validate a Monte Carlo-based TPS (Juste et al 2015).…”
Section: Applicationsmentioning
confidence: 99%
“…The second simulation corresponds to the water phantom and starts from the previous surface source generated with more than 10 7 collected particles. [8] To speed up the calculations without compromising the accuracy of the results, the MCNP6 (version 6.1.1) code has been parallelized in SENUBIO ISIRYM research group´s cluster Quasar using the MPI protocol with 26 processors. Finally, the computational real time real time was about 48 hours.…”
Section: Fig 3 Varian Clinac Meshed With Abaqus/caementioning
confidence: 99%