Use of multivariate curve resolution and a high-speed diode array ultraviolet detector in size-exclusion chromatography of lignin-based copolymers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

1987
1987
1995
1995

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 18 publications
0
10
0
Order By: Relevance
“…This method is quite sensitive for optical absorption and has been applied to trace analysis in parts-per-trillion (pg/mL) to sub-part-per-trillion levels (3,4). Trace analysis with PAS can be applied not only to true solutions but to turbid and colloidal solutions which are light scattering materials (5,6). Oda et al (5) have shown the sensitivity of PAS, that is the slope of the calibration curve, is independent of particle size, because the PA signal magnitude is proportional to the optical energy absorbed by the solution and is not affected by light scattering.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…This method is quite sensitive for optical absorption and has been applied to trace analysis in parts-per-trillion (pg/mL) to sub-part-per-trillion levels (3,4). Trace analysis with PAS can be applied not only to true solutions but to turbid and colloidal solutions which are light scattering materials (5,6). Oda et al (5) have shown the sensitivity of PAS, that is the slope of the calibration curve, is independent of particle size, because the PA signal magnitude is proportional to the optical energy absorbed by the solution and is not affected by light scattering.…”
Section: Resultsmentioning
confidence: 99%
“…Trace analysis with PAS can be applied not only to true solutions but to turbid and colloidal solutions which are light scattering materials (5,6). Oda et al (5) have shown the sensitivity of PAS, that is the slope of the calibration curve, is independent of particle size, because the PA signal magnitude is proportional to the optical energy absorbed by the solution and is not affected by light scattering. They showed that two calibration curves for a precipitated BaS04 mixture of 6-20 and 0.5-6 jim particles overlapped each other when the 514.5-nm lasing line of an Ar laser was used for the excitation beam.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This capacity allows spectra to be taken at numerous times during the elution of a chromatographic peak and is critical to prove the existence of graft copolymers by multivariate curve resolution. 10…”
Section: Methodsmentioning
confidence: 99%
“…used the initial version of the above software package to perform curve resolution of lignin-based copolymers analyzed by size-exclusion chromatography. 21 After construction of a calibration curve, quantitative results were obtained for unresolved peaks, allowing the researchers to estimate the concentration of a chromophore adduct in a particular molecular size fraction.…”
Section: Methods Based On Lawton and Sylvestre's Methodsmentioning
confidence: 99%