2000
DOI: 10.1007/s005350070087
|View full text |Cite
|
Sign up to set email alerts
|

Use of salivary acetaminophen concentration to assess gastric emptying rate of liquids

Abstract: The gastric emptying rate (GER) of liquids can be quantified by calculating the rate of acetaminophen absorption from serial plasma concentrations. As acetaminophen concentrations in saliva are well correlated with those in plasma, the salivary concentrations may be suitable for use in GER measurement. To evaluate such suitability, salivary and plasma samples were simultaneously obtained from seven healthy volunteers at 0, 0.25, 0.5, 0.75, 1.0, 1.5, and 2.0 h after they had ingested 20 mg/kg of acetaminophen m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
50
0
1

Year Published

2000
2000
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(56 citation statements)
references
References 36 publications
5
50
0
1
Order By: Relevance
“…The peak paracetamol concentration measured in saliva (Cmax) for the present study (4.0 -15.4 µg/mL) was in agreement with salivary paracetamol concentrations in other studies (5 -18.5 µg/mL) (Sanaka et al, 2000, Schaiquevich et al, 2002. Cmax and tmax are dependent on the extent and the rate of drug absorption, and measurement of these is influenced by the number of samples collected for analysis.…”
Section: Discussionsupporting
confidence: 91%
See 3 more Smart Citations
“…The peak paracetamol concentration measured in saliva (Cmax) for the present study (4.0 -15.4 µg/mL) was in agreement with salivary paracetamol concentrations in other studies (5 -18.5 µg/mL) (Sanaka et al, 2000, Schaiquevich et al, 2002. Cmax and tmax are dependent on the extent and the rate of drug absorption, and measurement of these is influenced by the number of samples collected for analysis.…”
Section: Discussionsupporting
confidence: 91%
“…When paracetamol powder dispersed in a nutrient drink was held in the mouth for 1 minute, oral contamination was believed to have affected salivary paracetamol measurements and affected reliability of the readings for up to 15 minutes (Sanaka et al, 2000). Furthermore, the use of 250 mL of water is not representative of what happens in practice for dysphagic patients using jam or thickened fluids to take their medicines, and may have altered the clearance from the stomach.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…These concentrations are relevant for successful detection in urine. 13,14 After stamping, we could not find the dry mark using bright-field microscopy because both molecules are colorless, however, SERS maps successfully provided the spatial distribution information of both. As shown in the bottom row of Fig.…”
Section: Resultsmentioning
confidence: 99%