1972
DOI: 10.1259/0007-1285-45-535-477
|View full text |Cite
|
Sign up to set email alerts
|

Use of stereoscopic X-ray pairs for measurements of airway length and diameterin situ

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

1974
1974
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…Pump (1964) found that the terminal bronchiole varied in diameter between 0 325 and 0 875 mm and that the respiratory bronchiole varied from 0 131 to 0 875 mm. These diameters vary with the degree of inflation of the lung (Hughes, Hoppin, and Wilson, 1972). An attempt was made to overcome the latter problem by maximally inflating the lung and taking radiographs when it was in a steady state.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Pump (1964) found that the terminal bronchiole varied in diameter between 0 325 and 0 875 mm and that the respiratory bronchiole varied from 0 131 to 0 875 mm. These diameters vary with the degree of inflation of the lung (Hughes, Hoppin, and Wilson, 1972). An attempt was made to overcome the latter problem by maximally inflating the lung and taking radiographs when it was in a steady state.…”
Section: Discussionmentioning
confidence: 99%
“…By using long focus film distances of between 100 and 200 cm the possible magnification error, due to the unknown position of the bronchi within the lung, was reduced to a maximum of 15%. It was therefore decided not to use the very accurate, but cumbersome tube shift method derived by Hughes et al (1972). The percentage error in the measurements, using a focal spot with an effective diameter of 1-6 mm and the focus film distances FIG.…”
Section: Discussionmentioning
confidence: 99%
“…The compliance of individual intrapulmonary airways is important in considerations of expiratory flow limitation but has been studied extensively only in the dog and in humans (Hughes et al, 1972;Martin and Proctor, 1958;Nakamura et al, 1981). Isolated peripheral airways that have less intrinsic airway wall support are more compliant than central airways but derive support in situ from attachments to the surrounding parenchyma.…”
Section: Compliance Of Intralobar Airwaysmentioning
confidence: 99%
“…These projects have investigated the bronchial tube thickness, 24,[30][31][32][33] material properties, 25,26,34,35 geometry, 36 and interaction with the parenchyma. 37,38 The interdependence of the bronchial tree and lung parenchyma has attracted attention since its introduction by Mead et al 39 The main goal is to estimate the effect of the bronchial tree on the overall behavior of the lung or vice versa.…”
mentioning
confidence: 99%
“…37,38 The interdependence of the bronchial tree and lung parenchyma has attracted attention since its introduction by Mead et al 39 The main goal is to estimate the effect of the bronchial tree on the overall behavior of the lung or vice versa. Hughes et al 36 studied the relationship between the airway deformation and rest of the lung. It is reported that the airway length changed by the cube root of the lung volume.…”
mentioning
confidence: 99%