Using antibacterial fibers and metallic wires to make woven fabrics used as smart diapers

Abstract: Cloth diapers also known as eco-diapers, traditional sandwich-structured eco-diapers are composed of top and bottom layers that are made of cotton or polyester nonwoven fabrics. On account of the hydrophilic bottom layer, urine permeates when the water absorption reaches saturation. In this study, polypropylene is melt-blown into hydrophobic polypropylene nonwoven fabrics to be used as the top and bottom layer. Polypropylene is hydrophobic but after being fabricated into nonwoven fabrics, the porous structure … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…A qualitative assessment antimic bial testing was used to evaluate the membranes by observing the inhibition zones of t test strains: Staphylococcus aureus (ATCC25923) and Escherichia coli (ATCC25922). The p tocol was performed according to the procedure described by Pinho et al and Shiu et [14] Each sample was tested at least five times. Next, the melt blending-coating method is used to produce TPU/triclosan compound membranes containing different triclosan contents.…”
Section: Measurements and Characterizationsmentioning
confidence: 99%
“…A qualitative assessment antimic bial testing was used to evaluate the membranes by observing the inhibition zones of t test strains: Staphylococcus aureus (ATCC25923) and Escherichia coli (ATCC25922). The p tocol was performed according to the procedure described by Pinho et al and Shiu et [14] Each sample was tested at least five times. Next, the melt blending-coating method is used to produce TPU/triclosan compound membranes containing different triclosan contents.…”
Section: Measurements and Characterizationsmentioning
confidence: 99%
“…[5][6][7] This traditional medical model does not allow individuals to participate in the monitoring of their own health, which is not conducive to the early diagnosis and predictive analysis of diseases. [8][9][10][11] In addition, with the outbreak of the coronavirus disease in 2019 (COVID- 19), the diagnostic steps are more complicated. 9 It is particularly important to realize personal health monitoring at home to meet the needs of users to acquire dynamic physiological state actively in time and achieve personalized medicine.…”
Section: Introductionmentioning
confidence: 99%
“…Typically, the electrodes are composed of noble metals (platinum or gold) attached to flexible substrates, such as polyethylene terephthalate (PET), polyvinylidene fluoride (PVDF) or polydimethylsiloxane (PDMS). 11,[18][19][20] Although these biosensor materials have high conductivity, due to the poor permeability it is difficult for them to meet the requirements of body heat and humidity comfort. 4,6,21 Considering that the intimate contact between the closed working electrode and human skin will destroy the dynamic balance of heat dissipation, wearing biosensors for a long time will lead to allergic reactions such as skin pruritus.…”
Section: Introductionmentioning
confidence: 99%