Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
42
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(44 citation statements)
references
References 22 publications
0
42
0
Order By: Relevance
“…In addition, for DTNB, a characteristic peak was also observed at around 1330 cm À1 (related to the C-N stretching vibrational mode). 16,47,48 The Raman signals of 10 À2 M 4-ATP and DTNB were both weak, whereas strong SERS signals were detected for 4-ATP/DTNB-labeled PDA@Ag-NPs. The analytical enhancement factor (AEF) for PDA@Ag-NPs was calculated using the equation AEF ¼ (I SERS /C SERS )/(I RS /C RS ), where C and I denote the concentration and intensity, and SERS and RS denote the SERS conditions and non-SERS conditions, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, for DTNB, a characteristic peak was also observed at around 1330 cm À1 (related to the C-N stretching vibrational mode). 16,47,48 The Raman signals of 10 À2 M 4-ATP and DTNB were both weak, whereas strong SERS signals were detected for 4-ATP/DTNB-labeled PDA@Ag-NPs. The analytical enhancement factor (AEF) for PDA@Ag-NPs was calculated using the equation AEF ¼ (I SERS /C SERS )/(I RS /C RS ), where C and I denote the concentration and intensity, and SERS and RS denote the SERS conditions and non-SERS conditions, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Although they achieved LODs of 500 pg/mL for three different cardiac biomarkers, they found that the calibration curve was nonlinear at high concentrations and the LOD varied depending on the detector. In subsequent work [ 30 ], they added Raman reporters to the nanoparticles and used SERS to create a calibration-free device with lower LODs. The improved LODs for the same cardiac biomarkers were 1–10 pg/mL, similar to their clinical cutoff values.…”
Section: Spectroscopic Detectionmentioning
confidence: 99%
“…In addition, an ECG examination has high requirements for equipment, which is challenging to meet the needs of POCT. Therefore, it is of great significance to detect cardiac markers with high sensitivity and specificity for early diagnosis of AMI ( Lim et al, 2020 ).…”
Section: Introductionmentioning
confidence: 99%