2014
DOI: 10.1016/j.microrel.2014.07.059
|View full text |Cite
|
Sign up to set email alerts
|

UV LEDs reliability tests for fluoro-sensing sensor application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 8 publications
0
6
0
1
Order By: Relevance
“…The process involved in obtaining these results has been extended over time: the authors studied the HP UV-LEDs with respect to the hydrocarbons comparing them with other classical light sources in [ 20 ], and later developed a series of experiments with two types of new commercial technologies 3W 365 nm HP UV-LEDs, characterizing the encapsulating, thermal, and electrical response in two working modes: continuous and cycled (30 s ON & 30 s OFF) [ 25 ], indicating the method and the preliminary results of the ALT [ 24 , 25 ] with these two types of UV-LEDs and the two working conditions in [ 24 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The process involved in obtaining these results has been extended over time: the authors studied the HP UV-LEDs with respect to the hydrocarbons comparing them with other classical light sources in [ 20 ], and later developed a series of experiments with two types of new commercial technologies 3W 365 nm HP UV-LEDs, characterizing the encapsulating, thermal, and electrical response in two working modes: continuous and cycled (30 s ON & 30 s OFF) [ 25 ], indicating the method and the preliminary results of the ALT [ 24 , 25 ] with these two types of UV-LEDs and the two working conditions in [ 24 ].…”
Section: Resultsmentioning
confidence: 99%
“…Fluorescence detection systems based on compact CCD spectrometer are emerging as a tool in research field applications [ 2 , 3 , 4 , 20 ]. In this work two compact spectrometers (Avantes ® Ava-Spec 2048-USB2-UA, and Mightex ® HRS-BD1-025) have been used, the first one for workbench instrumentation in signature readout, and the second one for analysis of UV-LED temperature ALT [ 24 , 25 ]. The spectra readout is obtained via a specific optical fiber of 0.6 mm Ø, solid angle Ω = 0.15 sr, numerical aperture NA = 0.22 ( Figure 2 a).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“… Se han realizado tres ensayos acelerados en temperatura sobre dos tipos de HP UV LEDs y dos modos de trabajo, dada la novedad del dispositivo y de la aplicación planteada, los resultados preliminares de estos ensayos fueron publicados en [ANVG14]. En la tesis se completan los resultados con las gráficas de degradación en cada ensayo y tipo de trabajo, la caracterización de la degradación que sufre cada tipo de LEd y como ha ocurrido dicho proceso, y por último la identificación de la energía de activación y esperanza de vida de cada Según la evolución de las curvas se propone tomar dos parámetros que representen resultados diferenciados, para así poder obtener alguna conclusión.…”
Section: Contribucionesunclassified