2011
DOI: 10.4172/2153-2435.s1-004
|View full text |Cite
|
Sign up to set email alerts
|

Validated HPLC Method for the Determination of Nisoldipine

Abstract: Experimental Materials and reagentsNisoldipine was supplied from NODCAR, Egypt, and its pharmaceutical form Sular tablets were manufactured by Rizhao Highrun Biotechnology Co., Ltd, China. All reagents and chemicals of the highest purity and analytical grade were available. Potassium dihydrogen phosphate and HPLC grade methanol were purchased from VWR. Hexane sulphonic acid sodium salt was obtained from Sigma-Aldrich. A standard stock solution 100 µg/ml of Nisoldipine was prepared in 100 ml methanol as solvent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…A good separation result was realized by the use of an LP-C 18 reverse phase column C18, 4.6 × 250 mm, set to 303 K and a mobile phase comprising aqueous solutions of methanol, 0.1 M hexane sulfonic acid sodium, and 0.01 M potassium dihydrogen phosphate (25:10:65, v/v) at pH 4.0 using orthophosphoric acid with a flow rate of 1.0 mL·min –1 . The UV detector was adjusted at a wavelength of 275 nm . Three samples were taken at a desired temperature for a given equilibrated system, and analysis for each sample was made three times.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A good separation result was realized by the use of an LP-C 18 reverse phase column C18, 4.6 × 250 mm, set to 303 K and a mobile phase comprising aqueous solutions of methanol, 0.1 M hexane sulfonic acid sodium, and 0.01 M potassium dihydrogen phosphate (25:10:65, v/v) at pH 4.0 using orthophosphoric acid with a flow rate of 1.0 mL·min –1 . The UV detector was adjusted at a wavelength of 275 nm . Three samples were taken at a desired temperature for a given equilibrated system, and analysis for each sample was made three times.…”
Section: Methodsmentioning
confidence: 99%
“…The UV detector was adjusted at a wavelength of 275 nm. 42 Standard uncertainties are 0.02 K for the determined temperature and 0.45 kPa for the atmospheric pressure; relative standard uncertainties are 0.0443 for the mole fraction solubility and 0.0002 for solvent mixtures in mass fraction. w, mass fraction of acetonitrile in the acetonitrile (w) + water (1 − w) mixture free of nisoldipine.…”
Section: ■ Modelsmentioning
confidence: 99%
“…The first two drugs have one chiral center in their molecular structure, while the third one has a stereogenic axis. These drugs are prescribed as racemic mixtures 4–6 . The enantiomers of these drugs have different pharmacodynamic and pharmacokinetic properties after being administered in the human body, leading to dosage confusion.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the above facts, US‐FDA, European Committee for Proprietary Medicinal Products, Pharmaceutical and Medical Devices Agencies of Japan, and Health Canada have banned the sale and marketing of all racemic drugs 10–12 . It is important to mention that it is necessary to separate the enantiomers of the racemic drugs and then market them for public use 13 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation