2011
DOI: 10.1016/j.chemphyslip.2011.04.009
|View full text |Cite
|
Sign up to set email alerts
|

Validation of an isotope dilution gas chromatography–mass spectrometry method for analysis of 7-oxygenated campesterol and sitosterol in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
66
2

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 47 publications
(70 citation statements)
references
References 38 publications
2
66
2
Order By: Relevance
“…The toluene dissolved samples were loaded onto a silica cartridge and allowed to pass through the column by gravity force at room temperature. Cholesterol, and non-cholesterol neutral sterols, including plant sterols, were eluted from the column with 8 Â 1.0 mL 0.5% 2-propanol in n-hexane (v/v) followed by elution of the OCS and OPS with 3 Â 1.0 mL 30.0% 2-propanol in n-hexane (v/v) as described by Dzeletovic et al and Husche et al [36,37]. To decrease workup duration and to avoid autoxidation vacuum equipment (Marchery-Nagel, Düren, Germany) was employed to accelerate the washing procedure.…”
Section: Sample Preparation For Simultaneous Analysis Of Ocs and Opsmentioning
confidence: 99%
See 2 more Smart Citations
“…The toluene dissolved samples were loaded onto a silica cartridge and allowed to pass through the column by gravity force at room temperature. Cholesterol, and non-cholesterol neutral sterols, including plant sterols, were eluted from the column with 8 Â 1.0 mL 0.5% 2-propanol in n-hexane (v/v) followed by elution of the OCS and OPS with 3 Â 1.0 mL 30.0% 2-propanol in n-hexane (v/v) as described by Dzeletovic et al and Husche et al [36,37]. To decrease workup duration and to avoid autoxidation vacuum equipment (Marchery-Nagel, Düren, Germany) was employed to accelerate the washing procedure.…”
Section: Sample Preparation For Simultaneous Analysis Of Ocs and Opsmentioning
confidence: 99%
“…where D baseline is the difference in abundance for the baseline of n-decane used blank sample, D analyt presents the difference in abundance for the analyte and c analyte is the absolute concentration of the analyte, evaluated by GC [37].…”
Section: Limits Of Quantification and Limits Of Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…7b-Hydroxy(OH)-campesterol, 7b-OH-sitosterol, 7-keto-campesterol and 7-keto-sitosterol were analyzed by gas chromatography-mass spectrometry (GC-MS-MS) according to the procedure as described by Husche et al [13] with minor modifications related to the use of a GC-MS triplequad instead of a GC-MS singlequad and are expressed as ng/mL.…”
Section: Blood Sampling and Analysesmentioning
confidence: 99%
“…Oxyphytosterols are present in plasma of healthy subjects and are markedly elevated in phytosterolemic patients [23,24]. However, controversy exist as to whether normo-phytosterolemic subjects treated with plant sterol enriched margarine have elevated levels of oxidized phytosterols [25,26].…”
Section: Introductionmentioning
confidence: 99%