2018
DOI: 10.1080/14763141.2018.1526316
|View full text |Cite
|
Sign up to set email alerts
|

Validation of an opto-electronic instrument for the measurement of weighted countermovement jump execution velocity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 34 publications
2
12
0
Order By: Relevance
“…Pen˜a Garcı´a-Orea et al 21 also performed a validity study of VW during a loaded CMJ in a Smith Machine over a range of intensities, revealing that VW was a valid and reliable tool to measure CMJ velocity, when compared to T-F. However, these authors reported the absolute values for mean and peak velocity from each device and the concordance correlation coefficient instead of reporting fixed or proportional bias between devices.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Pen˜a Garcı´a-Orea et al 21 also performed a validity study of VW during a loaded CMJ in a Smith Machine over a range of intensities, revealing that VW was a valid and reliable tool to measure CMJ velocity, when compared to T-F. However, these authors reported the absolute values for mean and peak velocity from each device and the concordance correlation coefficient instead of reporting fixed or proportional bias between devices.…”
Section: Discussionmentioning
confidence: 99%
“…VW was launched in 2017 and there are currently three validation studies stating that this device is valid and reliable to assess movement velocity during freeweight HS and countermovement jump (CMJ). [19][20][21] However, from a profound examination of these studies, the authors detect some limitations that make this study necessary. It is crucial to consider that the VW device is a camera-based system, only able to assess movement velocity in two dimensions.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The VS can determine the angle formed by two bone segments (with three reference points: One joint axis and two references) or, alternatively, between a bone segment and the horizontal/vertical line drawn on the joint axis. Depending on the camera’s proximity to the joint, the system’s accuracy has been reported to be between 0.1° and 1° [16], without influencing other operating system properties.…”
Section: Methodsmentioning
confidence: 99%
“…In spite of being a handy and easy to use tool, the utility of the WiiRemote TM to track points is limited to certain lighting conditions and a sampling rate of 100 samples per second [14]; thus new optoelectronic systems have emerged [15,16]. The VeloFlex system (VS) (Deportec, Murcia, Spain) is a new tool that can track up to four markers and provides real-time feedback with zero latency time.…”
Section: Introductionmentioning
confidence: 99%