2021
DOI: 10.1002/alz.056018
|View full text |Cite
|
Sign up to set email alerts
|

Validation of technology to monitor sleep and bed occupancy in older men and women

Abstract: Background: Nocturnal disturbance is frequently observed in dementia and is a major contributor to institutionalisation. Unobtrusive technology that can quantify sleep/wake and determine bed occupancy during the major nocturnal sleep episode may be beneficial for long-term clinical monitoring and the carer. Such technologies have, however, not been validated in older people. Here we assessed the performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…The clinimetrics of systems using multiple noncontact sensors were not yet optimal. Radar and pressure mats overestimated total sleep time and sleep accuracy in the laboratory among community-dwelling older adults [ 147 ]. The reliability of the measurements of heart rate and respiration rate of healthy adults and people with dementia differed depending on the setting [ 146 ].…”
Section: Resultsmentioning
confidence: 99%
“…The clinimetrics of systems using multiple noncontact sensors were not yet optimal. Radar and pressure mats overestimated total sleep time and sleep accuracy in the laboratory among community-dwelling older adults [ 147 ]. The reliability of the measurements of heart rate and respiration rate of healthy adults and people with dementia differed depending on the setting [ 146 ].…”
Section: Resultsmentioning
confidence: 99%
“…The Withings sleep analyzer is chosen due to its passive recording ability (ie, it does not need recharging or adjustments once installed) and previous collaboration between UK DRI and Withings that provides easy integration. Additionally, the Withings sleep analyzer has been evaluated and showed comparable results to actigraphy and polysomnography based sleep assessment, in older people [29]. In this study, we will analyze participants' sleep data to monitor the participants' objective sleep parameters based on respiration, heart rate, snoring, and apnea episodes.…”
Section: Design Engineering Processmentioning
confidence: 99%
“…The use of polysomnography provides the potential to target treatment for those patients with LC dysfunction that may be affecting the sleep–wake cycle 118 . New technologies have enabled higher quality home assessment of sleep physiology, and these are likely to lead to better diagnosis of sleep abnormalities 119 and targeted treatment approaches.…”
Section: Using Biomarkers To Guide Therapeutic Approachesmentioning