2020
DOI: 10.1515/cclm-2020-0535
|View full text |Cite
|
Sign up to set email alerts
|

Validation of the analytical performance of the NOVEOS™ System, a system which improves upon the third-generation in vitro allergy testing technology

Abstract: AbstractObjectivesDetection of allergen-specific immunoglobulin E (sIgE) is important for the diagnosis of allergy. IgE sensitization is commonly demonstrated in vivo by skin prick testing (SPT), or in vitro utilizing automated systems. Recently, HYCOR® Biomedical launched its new system for allergen sIgE testing c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 17 publications
0
9
0
Order By: Relevance
“…This was not surprising since the recombinant allergen molecules have a defined purity and biological activity 26 . In a preliminary study, 21 we had found that the NOVEOS test is a robust one, as it achieved good results in all the required parameters of the clinical validation performed at 2 sites. Concerning repeatability, it yielded a coefficient of variation of 2.6%–7.6%, and within‐lab precision ranged from 3% to 11.9%.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations
“…This was not surprising since the recombinant allergen molecules have a defined purity and biological activity 26 . In a preliminary study, 21 we had found that the NOVEOS test is a robust one, as it achieved good results in all the required parameters of the clinical validation performed at 2 sites. Concerning repeatability, it yielded a coefficient of variation of 2.6%–7.6%, and within‐lab precision ranged from 3% to 11.9%.…”
Section: Discussionmentioning
confidence: 95%
“…Interference was tested with methylprednisolone, diphenhydramine, omalizumab, biotin and ranitidine, and the obtained IgE recovery values were within the accepted variation. A comparison between the new systems' calibrators and the World Health Organization ones indicated a linear correlation with a high correlation coefficient of r = 0.994 and r = 0.997 for the 2 sites 21 …”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…The molecular SX01 test adopts a chemiluminescence detection system (NOVEOS, Hycor, USA) operating in a solid phase of fluorescently labeled and streptavidin-coated paramagnetic microparticles, already described elsewhere. 22 The microparticles are first incubated with a biotinylated allergen that binds the streptavidin molecules. After an extensive wash, the bound microparticles are then incubated with patient serum containing allergen-specific IgE, and the resulting bound complex is washed by aspirating unbound material from retained beads in the cuvette.…”
Section: Ige Chemiluminescent Platformmentioning
confidence: 99%