2019
DOI: 10.3390/ijerph17010193
|View full text |Cite
|
Sign up to set email alerts
|

Validity and Reliability of the WIMUTM Inertial Device for the Assessment of Joint Angulations

Abstract: Range of motion measurement is fundamental in the physical examination and functional evaluation of different joints. WIMUTM is an inertial device that allows the analysis of joint motion easily in real time. This study had a two-fold goal: (i) to evaluate the validity of WIMUTM on the measurement of different angle positions, compared with a standard goniometer and 2D video-based motion analysis software; and (ii) to evaluate the use of WIMUTM in the assessment of angulations in a joint, specifically assessin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…For data collection, players carried Wimu Pro ultra-wideband-based position-tracking system devices (RealtrackSystems, Almería, Spain). The system provides high ecological relevance for analysis of real training and match situations related to physical demands [ 26 ], and was previously validated in other studies on soccer [ 27 ] and basketball [ 28 ] where it was indicated as a valid and reliable inertial device for measuring dynamic weight-bearing ankle dorsiflexion [ 29 ] and angle positions for the assessment of joint range of motion [ 30 ]. Previous studies have also shown the satisfactory reliability and accuracy of results from the accelerometer under static and dynamic conditions [ 31 ], and proved the device to be valid and reliable for step counts, regardless of the level of physical activity [ 32 ].…”
Section: Methodsmentioning
confidence: 99%
“…For data collection, players carried Wimu Pro ultra-wideband-based position-tracking system devices (RealtrackSystems, Almería, Spain). The system provides high ecological relevance for analysis of real training and match situations related to physical demands [ 26 ], and was previously validated in other studies on soccer [ 27 ] and basketball [ 28 ] where it was indicated as a valid and reliable inertial device for measuring dynamic weight-bearing ankle dorsiflexion [ 29 ] and angle positions for the assessment of joint range of motion [ 30 ]. Previous studies have also shown the satisfactory reliability and accuracy of results from the accelerometer under static and dynamic conditions [ 31 ], and proved the device to be valid and reliable for step counts, regardless of the level of physical activity [ 32 ].…”
Section: Methodsmentioning
confidence: 99%
“…The WIMU system (WI) (RealTrack Systems, Almería, Spain) was established as the gold standard to establish the concurrent validity of FM measurements [19,[32][33][34]. It comprises a digital inclinometer displaying a range of 360 • marked in 0.1 • increments.…”
Section: The Gold Standardmentioning
confidence: 99%
“…A number of professionals, including physicians and physiotherapists, coaches, and athletic trainers have been performing objective outcome-based care, concerning for example joint angles, and thus, the use of valid and reliable instruments to measure the joint angle is imperative. The joint angle measures represent the index of change in sports functional performance or the evaluation outcome value to therapeutic interventions during rehabilitation programs ( García-Rubio et al, 2019 ; Lim, 2021 ; Oh et al, 2019 ). To achieve accurate and reliable results, highly skilled and well-trained operators are required to calibrate and run the 3D motion capture system; thus, they are not easily available to all professionals ( Krause et al, 2015 ).…”
Section: Introductionmentioning
confidence: 99%