Vapour-phase behaviour of slurries in electrothermal atomic absorption spectrometry

Abstract: The evolution of molecular and atomic vapours during the atomization of slurries has been followed ming an ultraviolet spectrophotometer with diode-array detection. Certified reference materials with an appropriate inorganic matter content were vaporized at 1700 "C, which gave rise to SiO molecules with a structured absorption between 200 and 250 nm. The same slurries, but prepared with HN03, when vaporized at the same temperature produced AI2C2 species. Atomization at 2200 "C led to the fast evolution of SiO … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

1994
1994
2004
2004

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 8 publications
0
2
0
1
Order By: Relevance
“…Spectral interferences can be more pronounced in slurry-ETAAS compared with solution analysis, and two separate reports described structured background that may not be corrected if continuum-source background correction is used. Biffi and Tittarelli (496,497) demonstrated an intense structured background absorbance between 200 and 280 nm when samples high in Si or Al are analyzed. Zeeman-effect background correction was satisfactory, but the use of a deuterium-lamp system resulted in a spectral error.…”
Section: Analysis Of Solids and Slurriesmentioning
confidence: 98%
“…Spectral interferences can be more pronounced in slurry-ETAAS compared with solution analysis, and two separate reports described structured background that may not be corrected if continuum-source background correction is used. Biffi and Tittarelli (496,497) demonstrated an intense structured background absorbance between 200 and 280 nm when samples high in Si or Al are analyzed. Zeeman-effect background correction was satisfactory, but the use of a deuterium-lamp system resulted in a spectral error.…”
Section: Analysis Of Solids and Slurriesmentioning
confidence: 98%
“…No entanto, esforços têm sido feitos no sentido de solucionar esta limitação dos instrumentos comerciais 46 e, paralelamente, vários instrumentos e sistemas multicanais baseados em arranjos lineares de fotodiodos têm sido descritos na literatura, em função das necessidades específicas dos usuários [47][48][49][50][51][52][53][54] . Os detectores de arranjo de diodos têm, naturalmente, amplas aplicações em determinações simultâneas sendo empregados em métodos com parada de fluxo (stopped-flow) 55,56 , cinéticos 57,58 , derivativos 59,60 , quimiométricos 61,62 e técnicas como cromatografia gasosa 63 , espectroeletroquímica 64,65 , espectrometria de absorção atômica 66,67 , de emissão atômica em plasma acoplado indutivamente 9,68 e espectrografia de emissão atômica 69 . Ainda, os espectrofotômetros PDA têm sido também empregados em determinações onde suas propriedades multicanais não são requisitadas 70,71 , ocupando um espaço antes reservado apenas para as fotomultiplicadoras.…”
Section: Parâmetrounclassified
“…ETV with a continuous source of radiation and an ultraviolet (UV) multichannel detector spectrometer was employed recently for the systematic study of UV absorption spectra of inorganic compounds. [1][2][3][4][5][6][7][8][9][10][11][12][13] The setup was initially developed by Tittarelli et al, [1][2][3][4] and later improved by Daminelli et al [5][6][7] Investigations of alkaline earth fluorides and chlorides, [8][9][10] indium nitrate and Group 3 halides, 11 sulfides, sulfates and sulfur 12,13 were also carried out with this technique. The main objective of these studies was to identify species responsible for the absorption of the UV radiation.…”
Section: Introductionmentioning
confidence: 99%