2010
DOI: 10.1016/j.radi.2010.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
14
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(17 citation statements)
references
References 22 publications
3
14
0
Order By: Relevance
“…Several studies have reported that software providing planes perpendicular the lumen centreline makes it possible to increase the reproducibility of the measurement. 2,7 Our results are only partially in accordance with these conclusions. With the semi-automated method, the mean diameters did not statistically differ between observers in our study.…”
Section: Planesupporting
confidence: 68%
See 2 more Smart Citations
“…Several studies have reported that software providing planes perpendicular the lumen centreline makes it possible to increase the reproducibility of the measurement. 2,7 Our results are only partially in accordance with these conclusions. With the semi-automated method, the mean diameters did not statistically differ between observers in our study.…”
Section: Planesupporting
confidence: 68%
“…Semi-automatic generation of the centreline by most software programs usually corresponds to the AAA lumen centreline, as it follows the path of the contrast medium in the aortic lumen. 2,7 The software we used in this study also created the lumen centreline. However, the AAA lumen centreline may differ from the actual centreline if the thrombus is asymmetrical, therefore leading to inaccurate aneurysmal cross sections.…”
Section: Planementioning
confidence: 99%
See 1 more Smart Citation
“…Per the methodology described by Bland and Altman, the difference between the observer's original and repeat measurements was calculated, followed by mean difference for analysis of intra‐observer variability; a similar approach was adopted for inter‐observer analysis . Pitman's test of difference in variance was used for statistical comparisons.…”
Section: Methodsmentioning
confidence: 99%
“…CT has become an important pre-operative imaging technique well as less operator dependent and more objective [4,9]. CT has various tools and techniques to measure the size of arteries [10][11][12], while in the present study, 2D axial sections were taken to measure the variation in size of the abdominal aorta.…”
Section: Introductionmentioning
confidence: 99%