2018
DOI: 10.3126/jie.v13i1.20358
|View full text |Cite
|
Sign up to set email alerts
|

Variations of Aerosol Optical Depth in Bhaktapur, Nepal

Abstract: Abstract:The study is based on the variations of aerosol optical depth in Bhaktapur, Nepal. Microtops II Sunphotometer, manufactured by solar light inc. USA was used to measure the Aerosol optical depth. The diurnal variations of Aerosol Optical Depth (AOD) in January, 9 at 2.32UT were found to be 1.01, 0.89, 0.81 and 0.61 at 340,440, 500 and 675nm respectively. Besides ozone and clouds, aerosol plays an influencing role to attenuate solar UV radiation reaching the ground. Spectral dependence of AOD possesses … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 9 publications
1
2
0
Order By: Relevance
“…This means that the submicron aerosol particle is dominant in this vicinity than that of coarse mode aerosol. The dominance of shorter wavelength AOD was also reported in different literatures [7,33,34]. Minimum aerosols loading in the atmosphere was observed during the month of January, which may be due to the weak generation mechanisms as well as the colder ground surface.…”
Section: Diurnal Variation Of Mean Aodsupporting
confidence: 74%
“…This means that the submicron aerosol particle is dominant in this vicinity than that of coarse mode aerosol. The dominance of shorter wavelength AOD was also reported in different literatures [7,33,34]. Minimum aerosols loading in the atmosphere was observed during the month of January, which may be due to the weak generation mechanisms as well as the colder ground surface.…”
Section: Diurnal Variation Of Mean Aodsupporting
confidence: 74%
“…5 the other channels have a bandwidth of 10 nm (Sharma, 2018;Tiwari et al, 2018). The full field of view of the instrument is 2.5°.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…We used a hand-held Microtops II sunphotometer (manufactured by Solar Light Company Inc., USA) containing five different interference filters at 340-, 440-, 500-, 675-, and 870 nm wavelengths and provides columnar information about aerosols. The sunphotometer works on the principle of extinction of solar radiation intensity at a certain wavelength and has the bandwidth of 2 nm at a 340 nm channel and 10 nm for rest of channels [8] [9]. The instrument has five accurately aligned optical collimators with 2.5° as a full field of view.…”
Section: B Instrumentationmentioning
confidence: 99%